Page 2-38
Xerox WorkCentre 450c/450cp Service Manual
RAP 8.0: Ni-Metal Battery
Use this RAP to test the WorkCentre’s
on-board Ni-Metal battery.
1. Remove the following:
•
Machine cover (REP 1.1).
•
Scanner assembly. (REP
4.1.9).
2. Use a voltmeter and test the output of
the battery.
Result:Battery voltage is 3.0 volts
or above?
No:
Replace the battery (REP 5.1.3:
Ni-Metal Battery on page 4-40). If
this does not solve the problem,
replace the main circuit board
(REP 5.1.2: Main Board on page
4-39).
Yes:
End of RAP.