Xerox WorkCentre 450c/450cp Service Manual
Page 6-35
S/W Switch 24
BIT No
NAME
Define
Default
Description
0
TCF CHECK
0 : Disable
1 : Enable
1
TCF signal error
check enable
2 ~ 1
DIS TIMER
00 : 3 Sec
01 : 3.45 Sec
10 : 2.55 Sec
11 : 4.5 Sec
00
DIS duration
4 ~ 3
CED FREQ
00 : 2100 Hz
01 : 1650 Hz
10 : 1100 Hz
00
Select frequency
of CED signal
5
RESERVED
7 ~ 6
ECM T5 TIMER
00 : 30 min
01 : 10 min
10 : 1 min
11 : 2 min
11
Line disconnect time
by RR response
8
ECM CTC
0 : Enable
1 : Disable
Do not care
9
LINE CURRENT
0 : Disable
1 : Enable
1
Enable off hook
detection
A
CFR 2 G3
0 : No
1 : Yes
0
Add time delay
before send CFR
B
RTN ERROR
0 : Go on when RTN
1 : Disconnect when RTN
0
Line disconnection
when receive RTN
D ~ C
RTC NUMBER
00 : 1
01 : 3
10 : 6
11 : 16
11
EOP numbers of
RTC signal
F ~ E
RESERVED