Page 6-16
Xerox WorkCentre 450c/450cp Service Manual
S/W Switch 7
BIT No
NAME
Define
Description
1 ~ 0
DIAL TONE DETECT
00 : OFF
01 : ON
10 : AUTO
Dial tone detection Mode
Auto mode is not used
3 ~ 2
DT_NUMBER
00 : 1
|
11 : 4 Times
The detection number of dial
tone in burst mode
6 ~ 4
DT_DETECT_WAIT_TIME
000 : PSTN_WAIT_TIME_3S
001 : PSTN_WAIT_TIME_5S
010 : PSTN_WAIT_TIME_10S
011 : PSTN_WAIT_TIME_15S
100 : PSTN_WAIT_TIME_20S
Waiting time to detect dial tone, if
there is no dial tone within this
time, it returns to IDLE state
9 ~ 7
DT_DIAL_START_TIME
000 : TONE_ON_500MS
001 : TONE_ON_800MS
010 : TONE_ON_1000MS
011 : TONE_ON_1500MS
100 : TONE_ON_2500MS
101 : TONE_ON_3500MS
110 : TONE_ON_4500MS
111 : TONE_ON_5500MS
Dial tone detection time in contin-
uous tone
A
DT_TONE_TYPE
0 : DT_CONTINUOUS
1 : DT_BURST
Dial tone type
C ~ B
RESERVED
D
LINE_DROP_TIME
0 : 6 sec
1 : 2.5 sec
HDLC line drop time
E
LONG_MARGIN
0 : 32 (when bottom margin =
12.7 mm)
1 : 95 (when bottom margin = 18
mm)
Printer vertical margin in using
LATOUR
F
MTF_DISABLE
0 : MTF enabled
1 : MTF disabled
Edge emphasis enable/disable