DOCUPRINT 4050, 4090, 4850, 4890, AND 92C IPS MESSAGES
XEROX DOCUPRINT IPS MESSAGES GUIDE
3-25
H032
Fuser under temperature fault.
The temperature of the fuser has fallen at least 35 degrees below the
required parameters.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
H033
Fuser control zero cross fault.
The MMB software is not receiving the signals required for fuser
control. In general, this indicates that a thermostat is open.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
H036
Output module configuration fault.
Either the IN@OUT@CONFIG setting is specified for a BFR
configuration and the output remote has an FOR board, or the
IN@OUT@CONFIG setting is specified for an FOR configuration
and the output remote has a BFR board.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
H037
HCFR failed memory or communication test.
The HCFR memory and communication test was unable to complete
successfully.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
H128
Toner waste bottle full.
The dry ink waste container is full.
Action
Replace the dry ink waste container, making sure the new waste
container is installed correctly, and press the [Continue] button.
(Refer to the
Xerox DocuPrint 4850/4890
or
92C IPS Guide to
Performing Routine Maintenance
for the procedure.)
H129
Patches for toner control are out of range.
The process patch used to control the toner dispenser was checked
six times and returned as white each time.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
H130
Ozone system failure.
The ozone blower activation switch failed.
Action
Press the [Continue] button. If the error persists, contact your service
representative.