DOCUPRINT 4050, 4090, 4850, 4890, AND 92C IPS MESSAGES
3-8
XEROX DOCUPRINT IPS MESSAGES GUIDE
E117
Late arrival at output tray switch.
The paper did not arrive at the output tray switch in time. A jam has
occurred.
Action
Clear the jam from areas 4 and 5 and press the [Continue] button. If
the error persists, contact your service representative. (Refer to the
Xerox DocuPrint 4850/4890
or
92C IPS Troubleshooting Guide
for
the procedure.)
E118
Page out of sequence detected in paper path.
An output page is in the incorrect sequence due to a feeding
problem, a software or firmware problem, or a fuser switch problem.
Action
Clear the jam from area 5 and press the [Continue] button. If the error
persists, check the fuser (area 4) for any jammed sheets. (Refer to
the
Xerox DocuPrint 4850/4890
or
92C IPS Troubleshooting Guide
for the procedure.)
E119
Late departure at bypass switch.
The paper did not leave the bypass switch in time.
Action
Clear the jam from area 6 and press the [Continue] button. (Refer to
the
Xerox DocuPrint 4850/4890
or
92C IPS Troubleshooting Guide
for the procedure.)
E120
Late departure from output tray switch.
The paper did not leave the output tray switch in time.
Action
Clear the jam from area 6 and press the [Continue] button. (Refer to
the
Xerox DocuPrint 4850/4890
or
92C IPS Troubleshooting Guide
for the procedure.)
E121
Left front door open.
The left front printer door is open.
Action
Close the left front printer door and retry the operation or press
Continue.
E124
All selected paper trays low on paper.
The paper supply is low in the paper trays selected for the job, or the
[Unlock] button was pressed for the paper trays you selected.
Action
Add more paper to the selected paper trays. Make sure the selected
paper trays are closed and press the [Continue] button.
E126
Late arrival at pre-transfer feeding from HCF.
The paper supply is low in the paper trays selected for the job, or the
[Unlock] button was pressed for the paper trays you selected.
Action
Check that the paper path is not obstructed. Check that the movable
baffles in Area 2 and 2A(HCF) are fully closed.