DOCUPRINT 96/4635/180 IPS MESSAGES
XEROX DOCUPRINT IPS MESSAGES GUIDE
2-39
09-202
AC voltage out of range.
The Coronode AC voltage is at or outside of the acceptable limits
during printing. This error is logged by the system.
Action
No action is required.
09-203
Photoreceptor end of life.
A photoreceptor belt failure was detected.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover.
09-211
Patch generator failure.
The patch generator cannot generate the amount of current that is
required to produce the necessary light output.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover.
09-212
IRD failure.
An IRD failure occurred.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover.
09-213
ESV failure.
An ESV failure occurred.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover.
09-215
Toner dispense failure.
A dry ink dispenser error occurred.
Action
Press the [Reset] button behind the printer control console front pull-
down cover.
09-220
Too long between belt holes.
The belt hole sensor made six unsuccessful attempts to detect belt
holes within the required spacing.
Action
Open the doors of the printer, clear areas 4, 5, 6, and 7, close the
doors, and retry the operation. (Refer to the
Xerox DocuPrint 96/
4635/180 IPS Troubleshooting Guide
for the procedure.)
09-221
Ozone blower air flow failure.
An inadequate air flow was detected by the ozone vacuum switch.
Action
Press the [Reset] button located behind the printer control console
front pull-down cover.