Commands and Queries Reference
Categories
Settings
Commands
and Queries
DLY
program the Power Module’s re-programming delay period.
DLY?
return the current re-programming delay period of the Power Module.
FOLD
program the type of Foldback to be used by the Power Module when
Current Limit is reached.
FOLD?
return the current Foldback selection of the Power Module.
ILIM
program an upper limit on subsequent programming of current settings
for the Power Module.
ILIM?
return the current value of the upper limit on ISET programming.
IMAX?
return the value of the Power Module’s output current rating.
IMIN?
return the value of the minimum programmable current limit for the
Power Module.
ISET
program the current limiting of the Power Module’s output.
ISET?
return the current programmed value of the Power Module’s output
current limit.
POLEN
enables the XMP 2600 to accept signed value parameters.
POLEN?
return the current state of the Polarity Enable Flag.
RAMP
program the Power Module’s Ramp Duration.
RAMP?
return the current Ramp Duration for the Power Module.
RIPL
program the Power Module to simulate ripple at its output.
RIPL?
return the current programmed output ripple for the Power Module.
VLIM
program an upper limit on subsequent programming of voltage settings
for the Power Module.
VLIM?
return the current value of the upper limit on VSET programming.
VMAX?
return the value of the Power Module’s output voltage rating.
VSET
program the voltage limiting of the Power Module’s output.
VSET?
return the current programmed value of the Power Module’s load voltage
limit.
Output
Control
Commands
and Queries
DISC
program the Power Module to connect or disconnect its output relay.
DISC?
return the state of the output relay.
OUT
program the state of the Global Output Enable Flag of the XMP 2600.
OUT
program the state of the Power Module Output.
OUT?
return the current state of the Global Output Enable Flag.
OUT?
return the current state of the Power Module’s output
POL
change the Power Module’s output polarity.
POL?
return the current output polarity of the Power Module.
Protection
Commands
and Queries
OCSET
program the Power Module’s Over Current Protection.
OCSET?
return the current programmed value of the Power Module’s OCP
threshold.
OVRST
reset OVP and OCP errors reported by the Power Module.
OVSET
program the Power Module’s Over Voltage Protection.
OVSET?
return the current programmed value of the Power Module’s OVP
threshold.
PROT
set-up the Protection Mode of the Power Module.
PROT?
return the current Protection Mode of the XMP 2600.
XMP 2600 Programming Manual
rev. 1.1