Commands and Queries Reference
Alphabetical
reference
ILIM
program an upper limit on subsequent programming of current
settings for the Power Module.
Syntax
ILIM
<ch>,<value>
Parameters
the number of the Power Module to be programmed.
the value to become the new upper limit for ISET
programming. The upper value of the programmed
value is IMAX.
Category Settings
Type:
Sequential
ILIM?
return the current value of the upper limit on ISET programming. The
response is a <value>.
Syntax
ILIM?
<ch>
Parameters
the number of the channel to be queried.
Category Settings
Type:
Sequential
ILOAD?
return output current measurement of the Power Module. The
response is a <value> (same as the IOUT? query).
Syntax
ILOAD?
<ch>
Parameters
the number of the channel to be queried.
Category Read-back
Type:
Sequential
ILOW
program the lower window warning level for the output current of the
Power Module.
Syntax
ILOW
<ch>,<value>
Parameters
the number of the Power Module to be programmed.
the value to be set as the lower window warning
level for the output current. The upper limit of the
programmed value is ISET.
Category Warnings
Type:
Sequential
ILOW?
return the current settings for the lower window warning level of the
output current of the Power Module. The response is a <value>.
Syntax
ILOW?
<ch>
Parameters
the number of the channel to be queried.
Category warnings
Type:
Sequential
IMAX?
return the value of the Power Module’s output current rating.
Syntax
IMAX?
<ch>
Parameters
the number of the channel to be queried.
Category Settings
Type:
Sequential
XMP 2600 Programming Manual
rev. 1.1
51