Alphabetical reference
Commands and Queries Reference
CMASK
program the positive and negative edge masks of the Events Filter
Mechanism.
Syntax
CMASK
<ch>,<int>,<int>
Parameters
The number of the Channel to which the masks are
being programmed.
The two integers are (respectively) the value of the
positive and negative masks. A bit value of “1”
enables the transition to generate an event while a bit
value of “0” disables it.
Category Status
Type:
Sequential
CMASK?
queries the value of the positive and negative edge masks of the
Events Filter Mechanism. The query return two numbers: positive
mask and negative mask.
Syntax
CMASK?
<ch>
Parameters
the number of the Channel to be queried.
Category Status
Type:
Sequential
CONF?
initiates a self-test of the XMP 2600 main control circuits. The tested
areas are: Controller Internal RAM, Tables Storage RAM, Settings
Storage Areas and Buffers RAM. The result of the self-test is reported
as a decimal number in the range 0 to 16 representing the bits of the
result register.
Syntax
CONF?
Parameters none
Category System
Type:
Sequential
CONF?
initiates a self-test of a Power Module. The tested areas are: Controller
Internal RAM, control circuit XMP 2600, analog section reference
voltage, D/A circuit and analog MUX. The result of the self-test is
reported as two decimal numbers in the range 0 to 255 representing
the bits of the result registers.
Syntax
CONF?
<ch>
Parameters
the number of the Power Module to be tested.
Category Status
Type:
Sequential
The self-test is a lengthy operation that is carried out in the background.
The CONF? Query initiates a self-test and returns the result of the
previously executed self-test.
46
XMP 2600 Programming Manual
rev. 1.1