Alphabetical reference
Commands and Queries Reference
VLIM?
return the current value of the upper limit on VSET programming. The
response is a <value>.
Syntax
VLIM?
<ch>
Parameters
the number of the channel to be queried.
Category Settings
Type:
Sequential
VLOAD?
return load voltage measurement of the Power Module. The response
is a <value>. If auto-polarity is enabled, negative output values will be
preceded with a minus sigh.
Syntax
VLOAD?
<ch>
Parameters
the number of the channel to be queried.
Category Read-back
Type:
Sequential
VLOW
program the lower window warning level for the load voltage of the
Power Module.
Syntax
VLOW
<ch>,<value>
Parameters
the number of the Power Module to be programmed.
the value to be set as the lower window warning
level for the load voltage. The upper limit of the
programmed value is VSET.
Category Warnings
Type:
Sequential
VLOW?
return the current settings for the lower window warning level of the
load voltage of the Power Module. The response is a <value>.
Syntax
VLOW?
<ch>
Parameters
the number of the channel to be queried.
Category warnings
Type:
Sequential
VMAX?
return the value of the Power Module’s output voltage rating.
Syntax
VMAX?
<ch>
Parameters
the number of the channel to be queried.
Category Settings
Type:
Sequential
VOUT?
return output voltage measurement of the Power Module. The
response is a <value>. If auto-polarity is enabled, negative output
values will be preceded with a minus sigh.
Syntax
VOUT?
<ch>
Parameters
the number of the channel to be queried.
Category Read-back
Type:
Sequential
66
XMP 2600 Programming Manual
rev. 1.1