Alphabetical reference
Commands and Queries Reference
DSP
remove a user message from the XMP 2600 front panel display.
Syntax
DSP
Parameters none
Category System
Type:
Sequential
DSP
display a message on the XMP 2600 front panel display.
Syntax
DSP
<string>
Parameters
the message to be displayed, limited to 21
characters. Extra characters are truncated.
Category System
Type:
Sequential
ERR?
return the last known Error Code of the XMP 2600 main controller.
The error code is cleared.
Syntax
ERR?
Parameters none
Category Status
Type:
Sequential
ERR?
return the last know Power Module error code. The error code is
cleared.
Syntax
ERR?
<ch>
Parameters
the number of the channel to be queried.
Category Status
Type:
Sequential
FOLD
program the type of Foldback to be used by the Power Module when
Current Limit is reached.
Syntax
FOLD
<ch>,<int>
Parameters
the number of the Power Module to be programmed.
the type of Foldback - a decimal value in the range 0
to 4, as detailed below:
0 = no Foldback
1 = retry Foldback
2 = linear Foldback
3 = nonlinear Foldback
4 = shutdown Foldback
See the “current limiting schemes” section of the
Basic Programming chapter for details on Foldback
behavior.
Category Settings
Type:
Overlapped
FOLD?
return the current Foldback selection of the Power Module.
Syntax
FOLD?
<ch>
Parameters
the number of the channel to be queried.
Category Settings
Type:
Sequential
48
XMP 2600 Programming Manual
rev. 1.1