Alphabetical reference
Commands and Queries Reference
*PRE
assign new value to the Parallel Poll Enable Register. Re-calculates
<ist>.
Syntax
*PRE
<int>
Parameters
the value to be assigned to the Register - a decimal
number in the range 0 to 255 representing bits in the
Register.
Category Status
Type:
Sequential
*PRE?
return the value of the Parallel Poll Enable Register. The value
returned is a decimal number in the range 0 to 255 representing the
bits of the Register.
Syntax
*PRE?
Parameters none
Category Status
Type:
Sequential
*PSC
controls whether or not the XMP 2600 will clear all the Event Enable
Registers and the SRQ and Parallel Poll Enable Registers at Power
On.
Syntax
*PSC
<int>
Parameters
a value of 0 disables the XMP 2600 from clearing
the Registers at Power On. Any other value (in the
range 1 to 255) enables clearing of the Register.
Category Status
Type:
Sequential
*PSC?
return the value of the Power On Status Clear Enable Flag: “0”
(disabled) or “1” (enabled).
Syntax
*PSC?
Parameters none
Category Status
Type:
Sequential
*RCL
restores settings of all the Power Modules (same as RCL command).
Syntax
*RCL
<int>
Parameters
a decimal number in the range 0 to 9 specifying the
storage number the XMP 2600 will restore the
settings from.
Category System
Type:
Overlapped
*RST
returns the XMP 2600 to its Power On state: send a Fault Reset
Command to all faulty Power Modules, if the Primary was shut down
then try to revive it, Initialize or Retain Power Modules Settings,
return the Front Panel Display to Normal Status Mode. Does not clear
the status structures (except for the Primary status).
Syntax
*RST
Parameters none
Category System
Type:
Sequential
42
XMP 2600 Programming Manual
rev. 1.1