Commands and Queries Reference
Warnings
Commands
and Queries
IHIGH
program the upper window warning level for the output current of the
Power Module.
IHIGH?
return the current settings for the upper window warning level of the
output current of the Power Module.
ILOW
program the lower window warning level for the output current of the
Power Module.
ILOW?
return the current settings for the lower window warning level of the
output current of the Power Module
VHIGH
program the upper window warning level for the load voltage of the
Power Module.
VHIGH?
return the current settings for the upper window warning level of the load
voltage of the Power Module.
VLOW
program the lower window warning level for the load voltage of the
Power Module.
VLOW?
return the current settings for the lower window warning level of the load
voltage of the Power Module
WHIGH
enable / disable window upper limits checks by the Power Module.
WHIGH?
return the state of the Power Module’s upper window check enable flag.
WLOW
enable / disable window lower limits checks by the Power Module.
WLOW?
return the state of the Power Module’s lower window check enable flag.
Read-Back
Queries
IALL? return
output
current
measurements of all operative Power Modules
ILOAD?
return output current measurement of the Power Module.
IOUT?
return output current measurement of the Power Module.
POWER?
return the XMP 2600 delivered output power.
VALL?
return load voltage measurements of all operative Power Modules.
VLOAD?
return load voltage measurement of the Power Module.
VOUT?
return output voltage measurement of the Power Module.
For their internal use (fault and warning detection), the Power Modules
generate a new read-back value every 40 mS.
The Main Controller is updated with new values (available for readback,
10 times a second.
Trigger and
Sync
Commands
and Queries
*TRG
toggles the state of the Global Output Enable Flag
ARM
program a Power Module to the Armed state in which further SET and
PROT programming will be stored with no immediate effect of the output
of the Power Module.
ARM?
return the state of the Power Module.
SYNC
program the Power Module’s Sync Pulse Generation Enable Event.
SYNC?
return the current Sync Pulse Generation Event for the Power Module.
TRIG
program the Power Module’s reaction to a software or hardware trigger.
TRIG?
return the current reaction to trigger for the Power Module.
TRIGER
send a global trigger (to all Power Modules).
TRIGER
send a trigger to the Power Module.
38
XMP 2600 Programming Manual
rev. 1.1