Self Test Results
Status reporting
BYTE 1
ANLG
MUX
DAC ANLG
REF
PWR
SUPPL
NOVR
AM_B
NOVR
AM_A
PROG
MEM
INT
RAM
INT_RAM....... Processor Memory.
PROG_MEM .. Program Memory.
NOVRAM_A.. Non-Volatile Memory A.
NOVRAM_B .. Non-Volatile Memory B.
PWR_SUPPL.. Control circuits power supplies
ANLG_REF .... Analog section reference voltage.
DAC................ Digital to Analog Converter.
ANLG_MUX .. Analog signal paths.
Light shaded bits are of tests performed during Power-On only.
Dark shaded bits are of tests performed during both Power-On and Power
Module Test.
A set bit indicates a fault.
BYTE 2
VSET
IOUT
VLOAD
VOUT
VOUT ............. VOUT measurement confidence test.
VLOAD .......... VLOAD measurement confidence test.
IOUT............... IOUT measurement confidence test.
VSET .............. VSET controlling signal confidence test.
Main
Controller
The Main Controller Confidence Test result is a single byte.
The results of the test can be remotely read using the CONF? query.
The result byte has the following format:
BUFF
AREA
SAVE
AREA
TABLE
AREA
INT
RAM
INT_RAM.............Processor Memory.
TABLE_AREA.....Main Memory - internal tables.
SAVE_AREA .......Main Memory - settings storage areas.
BUFF_AREA........Main Memory - communications buffers.
76
XMP 2600 Programming Manual
rev. 1.1