3-82 PC Setup
a.
Under Paper Source, if you select Manual Feed go to step 4.b; if not, skip
to 4.c.
b.
Under Manual Feed Options, if you are using standard size media, click
Standard Paper Size and select the size from the drop-down menu. If you
are using a custom size, click Custom Paper Size and enter the size and
select the unit of measure (inch, millimeter, or centimeter).
c.
Under Print Settings, select the resolution from the drop-down menu.
d.
Click OK. The More X-ACT window reappears (fig. 3.177).
5.
Click Print Calibration Page. A test page similar to the one shown in the
Calibration Page section prints (fig. 3.178).
D
D
Measure dashed line from top edge of
paper to right arrow tip; enter results in
millimeters in box D.
C
Measure solid horizontal line from left arrow
tip to right arrow tip; enter results in
millimeters in box C. This should be
close to the value shown in box H.
B
Measure dashed line from top edge of
paper to left arrow tip; enter results in
millimeters in box B.
A
B
C
F
A
Measure dashed line from left edge of
paper to top arrow tip; enter results in
millimeters in box A.
E
E
Measure solid vertical line from top arrow
tip to bottom arrow tip; enter results in
millimeters in box E. This should be
close to the value shown in box G.
F
Measure dashed line from left edge of
paper to bottom arrow tip; enter results in
millimeters in box F.
G
H
254.0
190.5
I
Measure dashed line from bottom edge of
paper to left arrow tip; enter results in
millimeters in box
I
.
J
Measure dashed line frombottom
edge of paper to bottom arrow tip;
enter results in millimeters in box J.
I
J
Fig. 3.177 More X-ACT Window
Fig. 3.178 Sample More X-ACT Calibration Page
6.
Make the measurements indicated on the calibration page next to boxes A
through F, I, and J, recording each measurement in its corresponding box on
the calibration page. The values in boxes G and H are fixed values and do not
require you to make any measurements.
7.
Copy the recorded measurements in boxes A through F, I, and J and the fixed
values in boxes G and H from the calibration page to the corresponding boxes
in the Enter Calibration Values section of the More X-ACT window.