Project Planning with the Universal Pro
3.1
Project planning
Planning the bus system
The following steps must be taken into consideration
when designing an installation:
1
Location of the machine or facility
2
Assignment of the signals to the installation to a
logical group
3
Selection of the field devices
4
Assignment of the signals to the field devices
5
Determination of where the field devices are to
be installed
Criteria for determining the correct SAI distributor:
Size of the connectors
Determine the size of the connectors to suit you application, the de-
sign of the sensors or according to your personal preferences.
Weidmueller offers both M12 and M8 variants for purely digital sig-
nals.
Number of poles of the I/O connec-
tions
Please consider the sensor/actuator cable to be connected; possi-
ble options are 3 or 5 poles.
T-piece
Specifically for 5-pole M12 sensor connections, you can feed two
cables to a distributor input by means of a Y-piece.
Inputs / outputs
Weidmueller has a variety of SAI distributors on offer such as a
variant with 16 digital inputs, with mixed digital inputs/outputs as
well as an analogue/digital version (for more information please re-
fer to Chapter 4: (Connecting SAIs).
Shielding
Shielding by means of metal connectors is necessary for bus con-
nections. We recommend the same approach for analogue signals
to restrict the susceptibility to interference.
Signals
Please consider if you wish to transmit analogue or digital signals.
Table 1
Determining the correct SAI distributor
You can find more information about determining the correct selection of products in Appendix A:
Product Overview.
16
5663600000/1.4/09.09
Содержание SAI Active Universal Pro Series
Страница 2: ......
Страница 10: ...Notes on Safety 10 5663600000 1 4 09 09...
Страница 11: ...SAI Pro 2 SAI Pro 2 1 Pro Description 12 2 2 PROFIBUS DP 14 5663600000 1 4 09 09 11...
Страница 20: ...Project Planning with the Universal Pro 20 5663600000 1 4 09 09...
Страница 23: ...Mounting SAIs Figure 7 Dimensions of extension I O with digital outputs 5663600000 1 4 09 09 23...
Страница 28: ...Mounting SAIs 28 5663600000 1 4 09 09...
Страница 95: ...Connecting the SAI Distributor 5663600000 1 4 09 09 95...
Страница 106: ...Commissioning the PROFIBUS DP 106 Figure 76 variable table counter value counter stop 5663600000 1 4 09 09...
Страница 177: ......