Diesel Gen-set Operation Instructions
58
Note: be sure that the Gen-set is not operated under no-load state continuously
for more than 30 minutes, in order to prevent leakage of lubricating oil of the
Gen-set.
Warning: do not try to touch exhaust pipe, turbocharger, high-temperature
coolant & heater and other high-temperature surfaces of the Gen-set with your
hands when the Gen-set is operating, or your hands would be burnt!
Warning: never remove any component of the Gen-set when the Gen-set is
operating!
Warning: when the Gen-set is operating, do not put your hands under protective
cover of fan or other parts which move relatively!
3. Warning of the Gen-set
Warning is not a serious alarm condition which would not have an impact on system
operation of engine, but only is used to remind operators of the conditions that do not
meet with requirements. When any warning occurs, display panel will display
corresponding trouble problems. If these troubles are not locked, the warning will be
removed once these troubles are eliminated. After troubles are eliminated, press
stop/reset button
to release stop locking, corresponding warning indicator light
will turns off and Gen-set is able to be started for commissioning.
4. Stop of the Gen-set
4.1 Normal stop
4.2 Remove loads at first, proceed to switching-off operation and let the Gen-set
operate without load for 3~5 minutes after being unloaded;
4.3 Press stop button
and the Gen-set will stop operating after 2 minutes (the
mechanically governing Gen-set will operate 2 minutes under rated conditions, while
electronic governing Gen-set will operate 2 minutes under idle mode);