Watlow PM LEGACY™ Limit Controller
•
118
•
Appendix
Ordering Information for Limit Controller Models
DR
AF
T
PM LEGACY Limit Model Configuration Information
① ②
PM
③
Package
Size
④
Primary
Functions
⑤
Power
Supply,
Digital I/O
⑥ ⑦
Output 1 and
2 Hardware
Options
⑧
Comm.
Options
⑨
Future
Option
A
⑫
Model
Selection
⑬ ⑭
Custom
Options
⑩ ⑪
Output 3 and
4 Hardware
Options
③
Package Size
3 =
1
/
32
DIN
(coming soon)
6 =
1
/
16
DIN
⑤
Power Supply, Digital Inputs/Outputs (I/O)
1 =
100 to 240VAC
2 =
100 to 240VAC plus 2 digital I/O points
(Not available on
Express version)
3 =
20 to 28VAC or 12 to 40VDC
4 =
20 to 28VAC or 12 to 40VDC, plus 2 digital I/O points
(Not
available on Express version)
⑥
Output 1 and 2 Hardware Options
Output 1
Output 2
AJ =
None
Mechanical relay 5A, Form A
CJ =
Switched dc/open collector
Mechanical relay 5A, Form A
EJ =
Mechanical relay 5A, Form C Mechanical relay 5A, Form A
⑦
⑧
Communication Options
Standard bus always included
A =
None
B =
Bluetooth®
E =
EIA-485 Modbus® RTU and Bluetooth®
(Not available on
Express version)
F =
Modbus® RTU 232/485 and Bluetooth®
(Not available on
PM3 or Express version)
G =
EtherNet/IP™/Modbus® TCP and Bluetooth®
(Not available
on PM3 or Express version)
H =
DeviceNet™ and Bluetooth®
(Not available on PM3 or
Express version)
J =
PROFIBUS DP and Bluetooth®
(Not available on PM3 or
Express version)
1 =
EIA-485 Modbus® RTU
(Not available on Express version)
2 =
EIA-232/485 Modbus® RTU
(Not available on PM3 or Express
version)
3 =
EtherNet/IP™/Modbus® TCP
(Not available on PM3 or
Express version)
5 =
DeviceNet™
(Not available on PM3 or Express version)
6 =
PROFIBUS DP
(Not available on PM3 or Express version)
Note:
Bluetooth® not available in all countries, contact factory.
④
Primary Functions
L =
Limit controller with universal input
M =
Limit controller with thermistor input
⑩
Output 3 and 4 Hardware Options
Output 3
Output 4
AA =
None
None
AJ =
None
Mechanical relay 5A, Form A
AK =
None
SSR Form A, 0.5 A
CA =
Switched dc/open collector
None
CC =
Switched dc/open collector
Switched dc
CJ =
Switched dc/open collector
Mechanical relay 5A, Form A
CK =
Switched dc/open collector
SSR Form A, 0.5 A
EA =
Mechanical relay 5A, Form C None
EC =
Mechanical relay 5A, Form C Switched dc
EJ =
Mechanical relay 5A, Form C Mechanical relay 5A, Form A
EK =
Mechanical relay 5A, Form C SSR Form A, 0.5A
FA =
Universal process
None
FC =
Universal process
Switched dc
FJ =
Universal process
Mechanical relay 5A, Form A
FK =
Universal process
SSR Form A, 0.5A
KK =
SSR Form A, 0.5A
SSR Form A, 0.5A
Note:
Only available on
1
/
16
DIN models if communication Options F,
G, H, J or 2 thru 6 is ordered in previous digit, then Option AA must
be ordered here.
⑪
⑫
Model Selection
G =
PM LEGACY Version
(Output 1 and 2 always isolated)
H =
PM LEGACY EXPRESS Version
(Available in PM3 or PM6)
(Output 1 and 2 always isolated)
⑬
Custom Options
WP =
Watlow logo face plate
WN =
No logo/no name face plate
AG =
Conformal coating
⑭
Watlow® and EZ-ZONE® are registered trademarks of Watlow Electric Manufacturing
Company.
SMOOTH-TOUCH™ and EZ-LINK™ are trademarks of Watlow Electric Manufacturing
Company.
UL® and cUL® are registered trademarks of Underwriter’s Laboratories, Inc.
i-Phone® is a registered trademark of Apple Corporation.
Android™ is a trademark of Google LLC.
To be automatically connected to the nearest
North American Technical Sales Offi ce:
1-800-WATLOW2 • www.watlow.com
International Technical Sales Offices:
Austria
+43 6244 20129 0
China
+86 21 3532 8532
France
+33 1 41 32 79 70
Germany
+49 7253 9400 0
India
+91 40 6661 2700
Italy
+39 02 458 8841
Japan
+81 3 3518 6630
Korea
+82 2 2169 2600
Mexico
+52 442 256 2200
Singapore
+65 6773 9488
Spain
+34 91 675 1292
Taiwan
+886 7 288 5168
UK
+44 115 964 0777
WIN-LEG-0720
©2020 Watlow Electric Manufacturing Company all rights reserved.
Powered by Possibility
Содержание PM LEGACY PM3
Страница 119: ...Watlow PM LEGACY Limit Controller 119 Appendix...