Watlow PM LEGACY™ Limit Controller
•
113
•
Appendix
Input Type
Max Error @ 25 Deg C
Accuracy
Range Low
Accuracy
Range High
Units
J
±1.75
0
750
Deg C
K
±2.45
-200
1250
Deg C
T
±1.55
-200
350
Deg C
Input Type
Max Error @ 25 Deg C
Accuracy
Range Low
Accuracy
Range High
Units
N
±2.25
0
1250
Deg C
E
±2.10
-200
900
Deg C
R
±3.9
0
1450
Deg C
S
±3.9
0
1450
Deg C
B
±2.66
870
1700
Deg C
C
±3.32
0
2315
Deg C
D
±3.32
0
2315
Deg C
F (PTII)
±2.34
0
1343
Deg C
RTD, 100 ohm
±2.00
-200
800
Deg C
RTD, 1000 ohm
±2.00
-200
800
DegC
mV
±0.05
-50
50
mV
Volts
±0.01
0
10
Volts
mAdc
±0.02
0
20
mAmps DC
mAac
±5
0
50
mAmps AC
Operating Range
Input Type
Range Low Range High
Units
J
-210
1200
Deg C
K
-270
1371
Deg C
T
-270
400
Deg C
N
-270
1300
Deg C
E
-270
1000
Deg C
R
-50
1767
Deg C
S
-50
1767
Deg C
B
0
1816
Deg C
C
0
2315
Deg C
D
0
2315
Deg C
F (PTII)
0
1343
Deg C
RTD (100 ohm)
-200
800
Deg C
RTD (1000 ohm)
-200
800
Deg C
mV
0
50
mV
Volts
0
10
Volts
mAdc
0
20
mAmps DC
Содержание PM LEGACY PM3