Burner Setup—Oil
E 3000
6.6
Adjusting the Air Settings
Factory
settings
Air band: 0
Air shutter:
6.5
Note:
These settings are initial settings only. Adjust the air settings as necessary to
obtain the proper smoke spot and combustion analysis values.
Background
There are two parts to adjusting the air setting: 1) air band; and 2) air shutter.
Adjust the air band to make large adjustments. Adjust the air shutter to make small
adjustments.
Effects
The air setting has the following effects on combustion.
Higher O
2
percentage (excess air settings) lowers soot production but raises
stack temperature and reduces efficiency: lean mixture.
Lower O
2
percentage (inadequate air settings) increases efficiency and lowers
stack temperature but may cause soot build-up: rich mixture.
Procedure
Follow the procedure below to adjust the air settings.
1. Initial setting of the air damper should be performed with the machine shut
down.
2. Loosen the air band locking screw
(a)
and the air shutter locking screw
(b)
.
3. Using the band position pointer
(c)
to determine position, move the air band to a
higher number to increase air volume. Turn it to a lower number to decrease air
volume.
4. Using the shutter position pointer
(d)
to determine position, move the air shutter
to a higher number on the shutter position pointer to increase air volume. Turn it
to a lower number to decrease air volume.
5. After the air settings have been made, tighten the band-locking screw
(a)
and
the shutter-locking screw
(b)
.
Result
The air settings have now been adjusted.
wc_gr008525
c
d
a
b
Содержание E3000
Страница 6: ...Foreword wc_tx002028gb fm 6...
Страница 22: ...Labels E 3000 wc_si000643gb fm 22 2 Labels 2 1 Label Locations 603 wc_gr008850 998 608 626 602 601 999 618...
Страница 39: ...ghi_tx001160gb fm 39 E 3000 Lifting and Transporting Notes...
Страница 44: ...wc_tx001951gb fm 44 Operation E 3000 4 5 Control Panel wc_gr008606 1 2 n d e f g h i j k l m a b c o p...
Страница 77: ...wc_tx001951gb fm 77 E 3000 Operation Notes...
Страница 95: ...ghi_tx001162gb fm 95 E 3000 Accessories wc_gr008559 2 1 1 2 x z a b c LR RR RS LS HX 50 HX 50 HX 50...
Страница 97: ...ghi_tx001162gb fm 97 E 3000 Accessories wc_gr008560 a b LR RR RS LS HX 50 HX 50...
Страница 99: ...ghi_tx001162gb fm 99 E 3000 Accessories wc_gr008561 a LR LS HX 50...
Страница 101: ...ghi_tx001162gb fm 101 E 3000 Accessories wc_gr008580 SPP HX 100 HX 100 HX 100 d e a b c LR RR y LS RS APP 2 1...
Страница 103: ...ghi_tx001162gb fm 103 E 3000 Accessories wc_gr008582 HX 100 HX 100 a b LR RR LS RS...
Страница 105: ...ghi_tx001162gb fm 105 E 3000 Accessories wc_gr008583 HX 100 a LR LS...
Страница 107: ...ghi_tx001162gb fm 107 E 3000 Accessories wc_gr008584 APP c e d DPP a b LR LS RR RS 2 1 HX 200 HX 200...
Страница 182: ...MSDS Dowfrost HD 50...
Страница 186: ...wc_tx001673gb fm 186 Fuji Temperature Controller...
Страница 199: ...Tire Safety Information...
Страница 200: ...wc_tx001952gb fm 200 Schematics E 3000 12 Schematics 12 1 Composite Schematic Machine with Oil Burner...
Страница 201: ...wc_tx001952gb fm 201 E 3000 Schematics 12 2 Composite Schematic Machine with Gas Burner...
Страница 205: ...wc_tx001952gb fm 205 E 3000 Schematics 12 4 Circulation System Circuit...
Страница 206: ...wc_tx001952gb fm 206 Schematics E 3000 12 5 Rewind System Circuit...
Страница 207: ...wc_tx001952gb fm 207 E 3000 Schematics 12 6 Gas Train Schematic...
Страница 208: ...wc_tx001952gb fm 208 Schematics E 3000 12 7 Generator...
Страница 213: ......