70
Parameter
Heating circuit pump
address A3:...
"ON"
"OFF"
–
9
–
10 °C
–
8 °C
–
8
–
9 °C
–
7 °C
–
7
–
8 °C
–
6 °C
–
6
–
7 °C
–
5 °C
–
5
–
6 °C
–
4 °C
–
4
–
5 °C
–
3 °C
–
3
–
4 °C
–
2 °C
–
2
–
3 °C
–
1 °C
–
1
–
2 °C
0 °C
0
–
1 °C
+1 °C
1
0 °C
+2 °C
2
to
+1 °C
to
+3 °C
to
15
+14 °C
+16 °C
Coding in the delivered condition
Possible change
A4:0
With frost protection (only for
weather-compensated control
units)
A4:1
No frost protection; this setting is on-
ly possible if code "A3:
–
9" has been
set.
!
Please note
"Important": Observe for cod-
ing address "A3".
A5:5
With heating circuit pump logic
function (economy control): Heat-
ing circuit pump is "OFF" when the
outside temperature (OT) is 1 K
higher than the set room tempera-
ture (RT
set
)
OT
>
RT
set
+ 1 K (only for weather-
compensated control units)
A5:0
Without heating circuit pump logic
function
A5:1
to
A5:15
With heating circuit pump logic func-
tion: Heating circuit pump "OFF",
see following table
Parameter address A5:...
With heating circuit pump logic function: Heating circuit pump "OFF"
1
OT
>
RT
set
+ 5 K
2
OT
>
RT
set
+ 4 K
3
OT
>
RT
set
+ 3 K
4
OT
>
RT
set
+ 2 K
5
OT
>
RT
set
+ 1 K
6
OT
>
RT
set
7
to
OT
>
RT
set
–
1 K
15
OT
>
RT
set
–
9 K
Codes
Coding level 2
(cont.)
5773 216 GB
Codes
Содержание B2TA
Страница 12: ...12 2 5 1 4 2x 3 Fig 5 Installing the boiler Removing the front panels 5773 216 GB Installation ...
Страница 13: ...13 1 2 SW17 Fig 6 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation ...
Страница 23: ...23 4 1 5 2 2x 3 Fig 16 Installing the boiler Fitting the front panels 5773 216 GB Installation ...
Страница 101: ...101 Parts lists Overview of assemblies 5773 216 GB Components ...
Страница 107: ...107 Parts lists Hydraulics 5773 216 GB Components ...
Страница 118: ...118 0004 0002 0005 0006 0001 0003 Fig 77 Parts lists Miscellaneous 5773 216 GB Components ...
Страница 142: ...142 5773 216 GB ...
Страница 143: ...143 5773 216 GB ...