61
Coding in the delivered condition
Possible change
Party mode time limit
F2:8
Time limit for party mode or exter-
nal operating program changeover
via button: 8 h (only for weather-
compensated control units)
*1
Note
Observe settings for coding ad-
dresses "3A", "3b" and "3C" in
group
"General"
, as well as "d5"
and "d8" in group
"Heating cir-
cuit..."
.
F2:0
No time limit.
*1
F2:1
to
F2:12
Time limit adjustable from 1 to 12 h
*1
Pump control in "Only DHW"
F6:25
In the "Only DHW" operating
mode, the internal circulation pump
is permanently on (only for con-
stant temperature control units)
F6:0
In the "Only DHW" operating mode,
the internal circulation pump is per-
manently off
F6:1
to
F6:24
In the "Only DHW" operating mode,
the internal circulation pump will be
started 1 to 24 times per day for
10 minutes each time.
Pump control in standby mode
F7:25
In "Standby mode", the internal cir-
culation pump is permanently on
(only for constant temperature con-
trol units)
F7:0
In "Standby mode", the internal cir-
culation pump is permanently off
F7:1
to
F7:24
In "Standby mode", the internal cir-
culation pump will be started 1 to
24 times per day for 10 min each
time.
Start temperature raising
F8:–5
Temperature limit for terminating
reduced mode
–
5 °C, see example
on page 130.
Observe the setting of coding ad-
dress "A3". (Only for weather-com-
pensated control units.)
F8:+10
to
F8:–60
Temperature limit adjustable from
+10 to
–
60 °C
F8:–61
Function not active
End temperature raising
F9:–14
Temperature limit for raising the re-
duced set room temperature
–
14 °C; see example on page 130
(only for control units for weather-
compensated operation)
F9:+10
to
F9:–60
Temperature limit for raising the set
room temperature to the value se-
lected for standard mode adjustable
from
+10 to
–
60 °C
Set flow temperature increase
FA:20
Raising the set boiler water or flow
temperature by 20 % when chang-
ing from operation with reduced
room temperature to operation with
standard room temperature. See
example on page 131 (only for
weather-compensated control
units).
FA:0
to
FA:50
Temperature rise adjustable from 0
to 50 %
*1
In the "Heating and DHW" program, party mode ends
automatically
when the system changes over to operation with
standard room temperature.
Codes
Coding level 1
(cont.)
5773 216 GB
Codes
Содержание B2TA
Страница 12: ...12 2 5 1 4 2x 3 Fig 5 Installing the boiler Removing the front panels 5773 216 GB Installation ...
Страница 13: ...13 1 2 SW17 Fig 6 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation ...
Страница 23: ...23 4 1 5 2 2x 3 Fig 16 Installing the boiler Fitting the front panels 5773 216 GB Installation ...
Страница 101: ...101 Parts lists Overview of assemblies 5773 216 GB Components ...
Страница 107: ...107 Parts lists Hydraulics 5773 216 GB Components ...
Страница 118: ...118 0004 0002 0005 0006 0001 0003 Fig 77 Parts lists Miscellaneous 5773 216 GB Components ...
Страница 142: ...142 5773 216 GB ...
Страница 143: ...143 5773 216 GB ...