42
3.
Disconnect the loading cylinder from the pipework
to prevent contamination from entering the pipe-
work.
4.
Remove loose deposits with a high pressure
cleaner.
!
Please note
When cleaning the inside,
only use plastic cleaning utensils.
5.
Use a chemical cleaning agent to remove hard
deposits that cannot be removed with a high pres-
sure cleaner.
!
Please note
Never use hydrochloric acid
based cleaning agents.
6.
Thoroughly flush the loading cylinder after cleaning.
Checking and replacing the magnesium anode (if required)
Check the magnesium anode. If it is discovered that
the anode has degraded to 10 to 15 mm Ø, we recom-
mend replacing the magnesium anode.
Re-assembling and filling the loading cylinder
Fig. 36
1.
Reconnect the loading cylinder to the pipework.
2.
Insert new gasket
A
underneath flange cover
B
.
3.
Fit flange cover
B
and tighten 8 screws
D
with a
maximum torque of 25 Nm.
4.
Push earth cable
C
onto the tab.
5.
Fit cover
E
.
6.
Fill the loading cylinder with potable water.
Commissioning, inspection, maintenance
Cleaning the loading cylinder
(cont.)
5773 216 GB
Содержание B2TA
Страница 12: ...12 2 5 1 4 2x 3 Fig 5 Installing the boiler Removing the front panels 5773 216 GB Installation ...
Страница 13: ...13 1 2 SW17 Fig 6 Installing the boiler Siting and levelling the boiler 5773 216 GB Installation ...
Страница 23: ...23 4 1 5 2 2x 3 Fig 16 Installing the boiler Fitting the front panels 5773 216 GB Installation ...
Страница 101: ...101 Parts lists Overview of assemblies 5773 216 GB Components ...
Страница 107: ...107 Parts lists Hydraulics 5773 216 GB Components ...
Страница 118: ...118 0004 0002 0005 0006 0001 0003 Fig 77 Parts lists Miscellaneous 5773 216 GB Components ...
Страница 142: ...142 5773 216 GB ...
Страница 143: ...143 5773 216 GB ...