4. Press the PP ENTER key again. The PRESET LED display remains with the number 95. The monitor will
display the power-up test screen (Figure 33) for the duration of its initial testing.
5. The Surveyor2000 then switches to the opening screen (Figure 34). This screen will display the camera
dome program version, current date/time, the current address and a request to send communications to
baud detect. Move the joystick or press buttons to send commands and commence auto-baud detect.
Troubleshooting
If the Surveyor2000 does not power-up correctly, check the following:
⇒
Verify, with a voltmeter, that 22 to 34 VAC is measured across TB1, pins 1 and 2. If not, check the
integrity of the power wiring. If less than 22 VAC is measured, it is probable that the power cable length is
too long. Check the maximum usable cable distance for the voltage input as stated in Table 7 of the
Technical Information section. If 22 to 34 VAC is measured, return the Surveyor2000 back to factory for
service in accordance with the Shipping Instructions section of this manual.
⇒
If the last screen displays and does not disappear, the Surveyor2000 is not communicating with the
control device. Verify that the Surveyor2000 address is selected on the control device. Sometimes
moving the joystick can begin communication. If communication cannot be established, check the
integrity of the control signal wiring. If all wiring is correct, swap the camera drive and re-check. If the new
camera drive communicates, return the Surveyor2000 back to the factory for service in accordance with
the Shipping Instructions section of this manual.
⇒
-45 connector. Also, verify that S2, switch 3 is set for Half Duplex in a
Half Duplex wired Surveyor2000.
⇒
ts run. If possible, check the output locally, with a portable monitor, at the actual
camera dome site.
If the Surveyor2000 is intermittently operational or operating independently, it is possible that the
communications (control) wiring is incorrect. Re-check proper placement of the control and response
signals on the terminal block or RJ
If the Surveyor2000 powers up but does not display any video, it is possible that there is a poor video
cable connection. Verify that BNC connectors are attached at the camera dome and monitor/CPU. In
addition, verify that the cable is not damaged. It is common for the cable to be stretched or squashed
somewhere along i
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Operation
•
47
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......