WARNING
: Connectors TB3 and J3 contain the same control signals. Therefore, wire the control cable to
TB3 OR J3, not both, to avoid communication errors.
WARNING
: If Vicoax mode is being used, DO NOT wire TB3 or J3 for control, as this will cause the
camera dome program to lock up upon power-up.
RJ-45
ALARM (J2)
J2-1
ALARM1
Alarm input 1
J2-2
VSSA
Ground
J2-3
ALARM2
Alarm input 2
J2-4
VSSA
Ground
J2-5
ALARM3
Alarm input 3
J2-6
VSSA
Ground
J2-7
ALARM4
Alarm input 4
J2-8
VSSA
Ground
TERMINAL BLOCK
COMM (TB3)
TB3-1
VSSA
Ground
TB3-2
RO+
Response out +
TB3-3
CI-
Command in -
TB3-4
RO-
Response out -
TB3-5
CI+
Command in +
RJ-45
COMM/RELAY (J3)
J3-1
CI+
Command in +
J3-2
RELAY NC
Relay, normally closed
J3-3
VSSA
Ground
J3-4
RO-
Response out -
J3-5
CI-
Command in -
J3-6
RELAY C
Relay, common
J3-7
RELAY NO
Relay, normally open
J3-8
RO+
Response out +
TERMINAL BLOCK
NVT (TB4)
TB4-1
UTP+
Universal Twisted Pair +
TB4-2
UTP-
Universal Twisted Pair -
TB4-3
GND
Ground
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Wiring
•
35
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......