The information in this manual covers the installation, configuration and operation of the Surveyor2000 
Camera Dome. This system should only be installed by a qualified technician using common hand tools and 
approved materials in accordance with national, state and local wiring codes. 

NOTE:

 Read all instructions before beginning any installation. 

 
The Surveyor2000 is a compact, lightweight intelligent security device comprised of a camera, pan/tilt drive, 
receiver and CPU-based electronics all in an attractive and covert enclosure. Surveyor2000 can be 
programmed and operated using any V1300X/V1400X/1500 series of NOVA communication devices and 
enhanced Vicoax II protocol. Surveyor2000 is sold in a variety of prepackaged configurations with choices in 
environment, mounting configuration, camera type, and lower dome finish. Models are also available for 
coaxial cable or twisted pair (UTP) video transmission. A UTP receiver is required for UTP transmission. 
Refer to Tables below for specific model numbers and options available. All versions use the same firmware 
for programming and operation. For programming, refer to the Surveyor2000 Programming Manual XX034. 
 
Surveyor2000 complies with UL standard 2044, CSA safety standard C22.2, No. 1, meets requirements for 
an FCC Class A computing device. Surveyor2000 complies with the fire code of certain local municipalities. 
The fire code for any given municipality should be verified for Surveyor2000’s compliance at the installation 
site. Vicon strongly recommends the use of line conditioners, voltage regulators and uninterruptible power 
supply (UPS) systems in the electrical pow

e

odels

Model Number 

t/ 

 

 

er service. 

Surv

Environmen

yor2000 M

Camera 

 

Mount

Produc
Code 

Cable Type 

Type/Format

Type 

Optical Zoom
Total Zoo

Lower 
Dome Type 

S2000-CC22-EX 8211-00 

Indoor/Coax  Color/NTSC Ceiling  22x/264x 

Not 

Included 

S2K-CC22NVT 8285-00 

Indoor/UTP Color/NTSC 

Ceiling 22x/264x 

Not 

Included 

S2000-CC22C-EX 8211-01 Indoor/Coax  Color/PAL Ceiling 22x/264x 

Not 

Included 

S2000-MC22-EX 8212-00 

Indoor/Coax  Mono/EIA Ceiling 22x/264x 

Not 

Included 

S2000-MC22C-EX 8212-01 Indoor/Coax  Mono/CCIR Ceiling  22x/264x 

Not 

Included 

S2000-CP22-EX 8213-00 

Indoor/Coax Color/NTSC Pendant 22x/264x 

Not 

Included 

S2K-CP22NVT 8286-00 

Indoor/UTP Color/NTSC Pendant 22x/264x 

Not 

Included 

S2000-CP22C-EX 8213-01 Indoor/Coax  Color/PAL Pendant 

22x/264x 

Not 

Included 

S2000-MP22-EX 8214-00 

Indoor/Coax  Mono/EIA Pendant 

22x/264x 

Not 

Included 

S2000-MP22C-EX 

luded 

8214-01 Indoor/Coax  Mono/CCIR Pendant 22x/264x 

Not 

Inc

S2000-CW22-EX 8215-00 

Outdoor/Coax Color/NTSC Pendant 22x/264x 

Clear 

S2K-CW22NVT 8287-00 

Outdoor/UTP 

Color/NTSCL Pendant  22x/264x 

Clear 

S2000-CW22C-EX 8215-01  Outdoor/Coax  Color/PAL Pendant 

22x/264x 

Clear 

S2000-MW22-EX 8216-00 Outdoor/Coax Mono/EIA Pendant 

22x/264x 

Clear 

S2000-MW22C
EX 

-

 

8216-01 Outdoor/Coa

Mono/CCIR Pendant

22x/264x 

Clear 

S2000-RC23 7003-00 

Indoor/coax 

Color/NTSC 
(day/night) 

Ceiling 23x/184x 

Not 

Included 

S2000-RC23C 7003-01 

Indoor/Coax 

Color/PAL Ceiling 23x/184x 

Not 

Included 

S2000-RP23 7004-00 

Indoor/Coax 

Mono/EIA Pendant 

23x/184x 

Not 

Included 

S2000-RP23C 7004-01 

Indoor/Coax 

Mono/CCIR Pendant 23x/184x 

Not 

Inc

Color/NTSC
(day/night) 
Color/NTSC
(day/night) 
Color/PAL 

luded 

S2000-RW23 7005-00 

Outdoor/Coax 

 

Pendant 23x/184x 

Clear 

S2K-RW23NVT 8288-00 

Outdoor/UTP 

 

Pendant 23x/184x 

Clear 

S2000-RW23C 7005-01 

Outdoor/Coax 

(day/night) 

Pendant 23x/184x 

Clear 

XX031-01 Rev 803 Surveyor2000 Camera Dome System 

Introduction  

  1 

Содержание SURVEYOR 2000 7003-00

Страница 1: ...situations and must not be used for this purpose Copyright 2003 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trade...

Страница 2: ......

Страница 3: ...sing Assembly 5 Installation 7 Quick Installation In Ceiling Model Ceiling Access 7 Quick Installation In Ceiling Model No Ceiling Access 8 Quick Installation Indoor Pendant 9 Quick Installation Outdo...

Страница 4: ...Line Jumpers JP1 JP2 JP3 for RS 485 Protocol Operation 41 Uninstalling the Surveyor2000 43 For an In Ceiling Installation 43 For a Pendant Installation 43 Operation 45 Initial Power Up 45 Verifying Pr...

Страница 5: ...odels Model Number t t m er service Surv Environmen yor2000 M Camera Mount Produc Code Cable Type Type Format Type Optical Zoom Total Zoo Lower Dome Type S2000 CC22 EX 8211 00 Indoor Coax Color NTSC C...

Страница 6: ...Code escription Model Num Produ D S2000 UWM 7032 Wall mount indoor outdoor S2000 UCM 7033 Ceiling mount indoor outdoor S2000 1PC UPM or 7428 Parapet mount outdo S2000 URM 7035 Roof mount outdoor S200...

Страница 7: ...lower dome care Refer to the subsequent sections of Installation Wiring Configuration and Operation for detailed descriptions of any method For Novice Installers Complete the remainder of this section...

Страница 8: ...lief fitting is used as an alternate means of providing support for cables on the In Ceiling Mount model when flexible conduit pipe is not used Refer to the In Ceiling Mount model sub section of the I...

Страница 9: ...e top of the Camera Drive There are variations in camera type for format magnification and day night usage Shroud The Shroud is a 5 4 in 137 mm textured black ABS plastic shell It has a 1 2 in 30 5 mm...

Страница 10: ...Figure 3 Surveyor2000 Outdoor Pendant Figure 2 Surveyor2000 Indoor Pendant 6 Introduction XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 11: ...n the specific unit purchased In Ceiling Indoor or Outdoor Pendant Quick Installation In Ceiling Model Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N XX031 01 Rev 8...

Страница 12: ...Quick Installation In Ceiling Model No Ceiling Access Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 8 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 13: ...Quick Installation Indoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N XX031 01 Rev 803 Surveyor2000 Camera Dome System Installation 9...

Страница 14: ...Quick Installation Outdoor Pendant Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N 10 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 15: ...ial occupying the space between the lower ceiling and upper building frame There are 2 methods of installation The first method is for ceilings with no access to the space above as in a typical hard m...

Страница 16: ...ing the nut and sliding it out Install the supplied strain relief fitting in its place and re attach the top cover Hold the enclosure near the hole in the ceiling and route approximately 9 inches 229...

Страница 17: ...7 rminal blocks TB1 and TB3 into the Communication Power Supply Board at the proper block frames 8 for coax installations or connect twisted pair video wires to screw terminal TB4 for UTP installatio...

Страница 18: ...with their mating standoffs and insert the camera drive into the enclosure When seated tighten the 3 captive screws 12 Lift the lower dome up to the Surveyor2000 and line up the 2 molded tabs on the...

Страница 19: ...ination box in this situation Detailed installation instructions will follow The ceiling material must provide a surface of suitable strength for the Surveyor2000 weight of 4 5 lb 2 0 kg on the area o...

Страница 20: ...e le or communication relay cable with an RJ 45 male connector if connectors J2 and J3 will be used Strip approximately 1 inch 25 mm of insulation off all wires to be terminated in Make all connectio...

Страница 21: ...S 422 mode will be used 1 Set switches 1 8 on DIP switch 1 S1 to Surveyor2000 s address as specified in Table 3 All addresses between 0 and 255 are valid address 0 is the same as camera number 256 2 S...

Страница 22: ...IP switch 2 S2 to either position as it does not affect Vicoax protocol operation NOTE DIP switches labeled ON or CLOSED and OFF or OPEN have the same meaning 10 Lift the lower dome up to the Surveyor...

Страница 23: ...the caddy rail clips to the existing frame Remove adjacent tiles to access the clips 3 Adjust the position of the caddy rail clips along the frame to obtain the best X position 4 Slide the assembly al...

Страница 24: ...and the Surveyor2000 weight of 5 7 lb 2 6 kg 1 Install the mount in accordance with the installation manual included with the mount or prepare the vertical 1 0 inch NPT pipe 2 Feed all necessary cable...

Страница 25: ...nication Power Supply Board s mating BNC connector at location J1 10 for coax installations or connect twisted pair video wires to screw terminal TB4 for UTP installations Plug in all RJ 45 cable conn...

Страница 26: ...ooking up until the arrow on the Installation Label is aligned with the arrow on the inside of the housing as shown in Figures 14c and 14d 17 Push the Surveyor2000 straight up into the housing as show...

Страница 27: ...m the ermination box must be mounted within the immediate area of the Surveyor2000 t The mount must provide a support of suitable strength for the sunshield housing and the Surveyor2000 1 ount or prep...

Страница 28: ...relay cable with an RJ 45 male connector if connectors J2 or J3 will be used WARNING If Vicoax mode is being used DO NOT wire TB3 or J3 with control signals as this will cause the camera dome program...

Страница 29: ...ockwise looking up until the arrow on the 8 Push the Surveyor2000 straight up into the housing as shown in Figures 17d and 9 Lift the lower dome up to the Surveyor2000 and press in its safety cord plu...

Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 31: ...nd the control system that requires two individually shielded twisted pair cables implex m the control system to the ESPONSE OUT RO A signal from the Surveyor2000 to the CPU in response to a COMMAND I...

Страница 32: ...ORMALLY OPEN NO ACTIVE LOW CLOSED Figure 20 Typical Relay Circuit The active state can be programmed through the Surveyor2000 menu system These signals are connected to RJ 45 Connector J3 Alarm signal...

Страница 33: ...NOTE If conduit pipe is not used the supplied strain relief fitting must be installed in place of the one installed to provide sufficient cable strain relief Figure 21 In Ceiling Mount Model Cable Ins...

Страница 34: ...cable stallation details 1 cut each cable The approximate total length of these cables should be 13 to 16 inches 330 to 406 mm 2 e Relay signals exist only in J3 Therefore remove TB3 only if the cont...

Страница 35: ...those connections Figure 22 Indoor Pendant Mount Cable Installation 8 Plug in all RJ 45 cable connectors to their corresponding mating connectors J1 and J3 WARNING Failure to insert the RJ 45 connecto...

Страница 36: ...le Figure 24 Feed the control cable into one of the sides and connect each wire to the appropriate screws Figure 26 is shown wired for typical Surveyor2000 duplex operation with no relay NOTE Upon ini...

Страница 37: ...from the control unit CPU or previous Surveyor2000 into one of the sides of the termination box and connect each wire to the appropriate screws 5 Feed the remaining control cable from the next sequent...

Страница 38: ...connection from open wires to open wires After the cable is passed through the cable fitting ceiling mounted Surveyor2000 only connect it to termination box s terminals When the cover of the terminat...

Страница 39: ...2 5 ALARM3 Alarm input 3 J2 6 VSSA Ground J2 7 ALARM4 Alarm input 4 J2 8 VSSA Ground TERMINAL BLOCK COMM TB3 TB3 1 VSSA Ground TB3 2 RO Response out TB3 3 CI Command in TB3 4 RO Response out TB3 5 CI...

Страница 40: ...GUI Call Technical Support at 1 800 34 VICON 1 800 348 4266 Standalone Configuration When one PC is being used with one dome the PC must be connected to the Surveyor2000 by means of Vicon s RS 232 RS...

Страница 41: ...udes the RS 232 RS 422 Interface Converter is used part number 1251 3555 01 In this configuration connect the converter end of the assembly to the COM 1 SERIAL port of the computer and the other end t...

Страница 42: ...System After the physical connections are made insert the S2000 PCSW disk and select the appropriate program Flash Upgrade Utility or PC Direct Control Software 38 Wiring XX031 01 Rev 803 Surveyor2000...

Страница 43: ...LEX OFF Position 4 is the protocol mode setting RS 485 ON or RS 422 OFF Each switch is numbered from 1 to 8 and marked to indicate the ON position Surveyor2000 will automatically detect the system s b...

Страница 44: ...X X X 42 X X X 128 X 214 X X X X X 43 X X X X 129 X X 215 X X X X X X 44 X X X 130 X X 216 X X X X 45 X X X X 131 X X X 217 X X X X X 46 X X X X 132 X X 218 X X X X X 47 X X X X X 133 X X X 219 X X X...

Страница 45: ...or2000 to access the jumper sockets Refer to the Uninstalling the Surveyor2000 section of this manual 2 Install all 3 jumpers by pushing them over the 2 pins for each socket on a Surveyor2000 which is...

Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 47: ...the ceiling It will hang from the safety cord Refer to Figure 31 3 If it is necessary to completely remove the camera drive disconnect the safety cord clip and all cables For a Pendant Installation 1...

Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 49: ...the AC power on to the Surveyor2000 The monitor will display the power up test screen Figure 33 for the duration of its initial testing This test displays the status of the functions pan tilt zoom fo...

Страница 50: ...isplays the Surveyor2000 Main Menu as shown in Figure 35 5 Set up the Surveyor2000 as desired using the remote keypad Proper operation has been verified Use of the Auto Baud Detect Feature Entering Pr...

Страница 51: ...yor2000 is not communicating with the control device Verify that the Surveyor2000 address is selected on the control device Sometimes moving the joystick can begin communication If communication canno...

Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 53: ...inside to the outer edge Use a new wick for each 2 passes over the dome Clean the lower dome s exterior with any soft nonabrasive cleaning cloth and a cleaning agen 5 t suitable for acrylic plastic Ei...

Страница 54: ...5 mAh It will be necessary to replace the battery when upon power up the time is reset and the previous programming configuration is reset to factory defaults The battery is accessible on the camera d...

Страница 55: ...ted Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit icon employee who issued...

Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...

Страница 57: ...deo quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approve...

Страница 58: ...Belden are used Materials and construction must follow the guidelines above ecommended Individually Shielded Twisted Pair Cable Types P receiver is required Vicon offers three ceivers to provide vide...

Страница 59: ...tion Outdoor 48 0 W nominal heater included Outdoor 2 7 btu min 0 6 cal min Note Indoor 28 8 W nominal Heat Equivalent Indoor 1 6 btu min 0 4 cal min These figures represent the conversion of 100 of t...

Страница 60: ...to end Preset Capabilities 79 individual programmable preset positions 8 tours available with 32 programmable events per tour Events may be preset positions alarm alarm or preset dwell times relay fu...

Страница 61: ...re Range RS 422 or RS 485 protocol selectable via DIP switch S2 Communication is simplex or half duplex operation at superimposed data on composite video signal automatically detec C On screen menu dr...

Страница 62: ...1 Indoor Coax Mono CCIR Pendant 22x 264x Not Included S2000 CW22 EX 8215 00 Outdoor Coax Color NTSC Pendant 22x 264x Clear S2K CW22NVT 8287 00 Outdoor UTP Color NTSC Pendant 22x 264x Clear S2000 CW22C...

Страница 63: ......

Страница 64: ...ters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far...

Отзывы: