Indoor Pendant Model
The Indoor Pendant model mounts on a Vicon mount (refer to the table in the Introduction section) or a 1.0-
inch vertical pipe. The pipe is a standard 1.0-inch NPT type and must be oriented vertically so the
Surveyor2000 can effectively hang from the pipe.
The mount is installed with all the cables run through it and the 1.0-inch NPT pipe is prepared for
Surveyor2000 installation. The cables are routed through the housing and the housing is screwed tightly to
the pipe. Then the Surveyor2000 is hung from the housing safety cord while it is wired and configured. The
Surveyor2000 is then carefully snapped into the housing. The Surveyor2000 is supported by the mount. The
indoor lower dome is then anchored with its safety cord and snapped on. Refer to Figure 13. Detailed
installation instructions will follow.
The accessory kit containing the RJ-45 to RJ-45 8 foot (2.4 m) cable and RJ-45 termination box can be used
for wiring the 4 alarms or the relay in this installation. Since the supplied cable is limited to 8 feet (2.4 m), the
termination box must be mounted within the immediate area of the Surveyor2000. The mount must provide a
support of suitable strength for the housing and
the Surveyor2000 weight of 5.7 lb (2.6 kg).
1. Install the mount in accordance with the
installation manual included with the mount or
prepare the vertical 1.0-inch NPT pipe.
2. Feed all necessary cables through the back of
the mount and out the end of the 1.0-inch NPT
Pipe, 16-inches (406 mm) in length.
3. Lift the housing up to the mount or pipe and
feed the cables through its top opening.
4. Place the housing onto the 1.0-inch pipe and
screw clockwise, looking up at the housing.
When snug, turn an additional quarter-turn.
5. Verify that each cable drops from the pipe
opening at least 16-inches (406 mm) in length.
6. Lift the Surveyor2000 up to the housing and
attach the housing’s safety cord to the
Surveyor2000’s latch. Allow the Surveyor2000
to hang from the housing.
7. Route each cable from the inside top of the
housing down to the cable retainer on the
enclosure and then comfortably over to its mating connector on the Communications/Power Supply
Board. Add 1-inch (25 mm) of extra length to each cable for termination and cut them. The approximate
length of each cable should be 13 - 16-inches (330 - 406 mm).
Figure 13
Indoor Pendant Mount Model
. Terminate all the cables as follows:
8
a) Remove terminal blocks TB1 and/or TB3. Since the control signals exist in both TB3 and J3, do not
remove TB3 if J3 will be used for control signal wiring.
20
•
Installation
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......