Using the Accessory Kit’s
Termination Box and RJ-45 Cable
for Wiring
Figure 24
Use of Accessory Kit Cabling
The Termination Box and RJ-45 Cable are
provided to assist in using connector J3.
Connector J3 is required to access the internal
relay and is an alternate connector for access to
the Surveyor2000’s control signals. The RJ-45
Cable has two male ends that plug directly into
connector J3 and the termination box. Since the
RJ-45 cable is 10 feet (2.5 m), the termination box
must be mounted within the vicinity of the
Surveyor2000.
The termination box provides a convenient
adapter from the RJ-45 connector to individual
wires. After the cable is passed through the cable
fitting (ceiling-mounted Surveyor2000 only),
connect it to termination box’s jack.
When the cover of the termination box is removed,
the pre-wired terminal block will resemble Figure
24. Feed the control cable into one of the sides
and connect each wire to the appropriate screws.
Figure 26 is shown wired for typical Surveyor2000
duplex operation with no relay.
NOTE
: Upon initial installation of a ceiling-
mounted Surveyor2000, it is
recommended to pass this RJ-45
connector through the fitting first. After
this, the remaining connectors that do not
fit through the fitting must be cut off and
terminated later.
NOTE
: Use only the supplied Vicon RJ-45 cable
or shielded equivalent.
Recommended Use of the Termination
Box with Flexible Conduit
Figure 25
Use of a Break Out Box for Termination Box
Mounting
If it is necessary to keep the control cable within
flexible conduit, it will be necessary to obtain a
break-out box. The termination box is then
mounted inside it and can have flexible conduit run
to it from both sides, as shown in Figure 25. This
method maintains a flexible conduit cover over all
cables and provides secure mounting of the
termination box.
32
•
Wiring
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......