The accessory kit containing the RJ-45 to RJ-45
10 foot (2.5 m) cable and RJ-45 termination box
can be used in this installation for the 4 alarms
or relay. Since there is no access to above
ceiling space and the supplied cable is limited to
10 feet (2.5 m), the termination box must be
mounted in an area with access. In addition, the
10 foot (2.5 m) cable must be routed discretely
with the other cables or through the flexible
conduit pipe. Refer to Figure 6 for an example
of using the supplied cable and termination box
in this situation.
Figure 6
Typical use of Accessory Kit
The ceiling material must provide a surface of suitable strength for the Surveyor2000 weight of 4.5 lb (2.0 kg)
on the area of the two flippers. Refer to the
Optional Independent Support
sub-section for installations
requiring additional support.
1. Mark, with the scribe, and cut a 7-3/8-inch (187 mm) diameter hole in ceiling at the desired location. Feed
all flexible conduit pipe or cables down through the hole.
2. Remove the camera drive from the enclosure by loosening the 3 captive screws.
3
. If cables are used without the use of flexible conduit:
a) Remove the enclosure’s top cover by loosening the 3 screws and lifting it off. Then remove the
conduit fitting by loosening the nut and sliding it out. Install the supplied strain relief fitting in its place
and re-attach the top cover.
Hold the enclosure near the hole in the ceiling and route approximately 9 inches (229 mm) of cables
through the strain relief fitting. Tighten the 2 strain relief fitting screws to compress the cables. Do not
b)
over-tighten the screws and crush the cables.
NOTE:
Connectors that do not fit through the strain relief fitting must be cut off and re-terminated after
passing the cable through. It is recommended to pass any RJ-45 connectors through the fitting first.
BNC type connectors do not fit through the fitting and must be terminated later.
3. If cables are channeled through flexible conduit:
a)
n the ceiling and route approximately 9 inches (229 mm) of conduit
cables through the conduit fitting.
b) Insert the end of the flexible conduit pipe into the conduit fitting and tighten the clamp screw.
NOTE:
Hold the enclosure near the hole i
Connectors that do not fit through the conduit fitting must be cut off and re-terminated after passing
the cable through. It is recommended to pass any RJ-45 connectors through the fitting first. BNC type
connectors do not fit through the fitting and must be terminated later.
4. Lift enclosure up through ceiling hole, turn and tighten flipper screws.
5. Connect the latch of the camera drive to the enclosure’s safety cord clip.
12
•
Installation
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......