NOTE
: Connectors that do not fit through the strain relief fitting must be cut off and re-terminated after
passing the cable through. It is recommended to pass any RJ-45 connectors through the fitting first.
BNC type connectors do not fit through the fitting and must be terminated later.
4. If cables are channeled through flexible conduit:
a) Route approximately 9 inches (229 mm) of conduit cables through the conduit fitting.
b) Insert the end of the flexible conduit pipe into the conduit fitting and tighten the clamp screw.
NOTE
: Connectors that do not fit through the conduit fitting must be cut off and re-terminated after passing
the cable through. It is recommended to pass any RJ-45 connectors through the fitting first. BNC type
connectors do not fit through the fitting and must be terminated later.
. Terminate all the cables as follows (refer to Figure 9):
5
a) Remove terminal blocks TB1 and/or TB3. Since the control signals exist in both TB3 and J3, do not
remove TB3 if J3 will be used for control signal wiring.
b)
terminal blocks. Then
strip approximately 0.25 inches (6 mm) of insulation off of each individual wire.
c)
ust also be used. Insert each wire into its proper terminal block location and tighten each
screw.
) Terminate the video (coaxial) cable with a BNC type male connector.
e)
le or communication/relay cable with an RJ-45 male connector,
if connectors J2 and J3 will be used.
Strip approximately 1 inch (25 mm) of insulation off all wires to be terminated in
Make all connections to terminal blocks TB1 and TB3 with reference to Table 2. On TB3, the
COMMAND IN + (CI+) and COMMAND IN - (CI-) connections must be used for Simplex operation.
For Half Duplex operation, the additional signals RESPONSE OUT + (RO+) and RESPONSE OUT -
(RO-) m
d
Terminate the 8-conductor alarm cab
WARNING
:
with control signals, as this will cause
If Vicoax mode is being used, DO NOT wire TB3 or J3
the camera dome program to lock up upon power-up.
Reinstall the te
6.
rminal blocks TB1 and TB3 into the Communication Power Supply Board at the proper
7.
(for coax installations) or connect twisted-pair video wires to screw terminal TB4
Plug in all RJ-45 cable connectors to their corresponding mating connectors J2 and J3. All cables should
block frames.
Install the video BNC cable connector to the Communication/Power Supply Board’s mating BNC
connector at location J1
(for UTP installations).
8.
be carefully looped around to prevent the excess cable from bending sharply and breaking later.
WARNING
: Failure to insert the RJ-45 connectors into the correct mating connectors can cause damage
to the Communication Power Supply Board upon power-up.
NOTE
: Failure to loop the cables can prevent later removal of the camera drive from the enclosure.
16
•
Installation
XX031-01 Rev 803 Surveyor2000 Camera Dome System
Содержание SURVEYOR 2000 7003-00
Страница 2: ......
Страница 30: ...NOTES 26 Installation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 46: ...NOTES 42 Configuration XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 48: ...NOTES 44 Uninstalling the Surveyor2000 XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 52: ...NOTES 48 Operation XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 56: ...NOTES 52 Shipping Instructions XX031 01 Rev 803 Surveyor2000 Camera Dome System...
Страница 63: ......