52
•
Video Switch Action
XX009 Rev 1099 NOVA V1400
Salvos are defined as discussed in the
Edit Salvo Switch
screen on page 53.
It is not required that the total number of steps be defined. Maintain the default salvo number and dwell
settings of 00 for undefined steps.
Note: Press the F2 key to insert a blank line. Press the F3 key to delete a line.
Menu Path: Main Menu
→
Video Switch Action
→
Edit Sequential Tour
→
Edit Tour
Settings:
Step:
01 to 32
Salvo Number: 00 to 64
Dwell:
00 to 60 seconds
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Set Last Step Action
The action that will take place when the final step in a tour has been performed is defined as the last step
action. Three last step actions are possible: another tour may activate (Chain), all touring may cease (Halt), or
the tour may repeat (Repeat).
The tour number and the total number of steps are listed at the top of this screen. These settings may not be
edited in this screen. The tour number is specified as discussed on page 50. The number of steps is defined
for each tour as discussed in
Define a Monitor Tour
on page 51 or
Define a Salvo Tour
on page 51.
Menu Path: Main Menu
→
Video Switch Action
→
Edit Sequential Tour
→
Set Last Step Action