10
•
Administration
XX009 Rev 1099 NOVA V1400
Event Number
The maximum number of timed events in the control system is 64. This maximum does not apply to events
which are not timed. Any combination of events may be identified as timed events. For example, a
configuration might include 20 timed presets, 30 timed salvos, 4 timed tours, and 10 timed enabled alarms.
Settings:
01 to 64
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Event Type
There are five timed event types available in the control system. Tours, salvos and presets define video
switching functions. The Tour setting is used to select a video switching function defined as a series of preset
video displays from various camera stations on a specified monitor or on various monitors, depending upon
the tour type. The tour type may be monitor or salvo, as discussed in
Select
Tour Type
on page 50. A group of
monitors displaying video from predefined camera stations may be defined as a Salvo. The Preset setting
specifies the pan, tilt, lens preset position and settings to be recalled when the event is selected.
The Alarm Enable setting specifies the pattern of alarms to be enabled. This allows an event to be
programmed which automatically enables one pattern of alarms for daytime monitoring and a different pattern
for nighttime surveillance, for example. The Alarm Type setting specifies that a pattern of alarms, with each
alarm in the pattern set to operate as momentary or latching, will be scheduled as a timed event. Therefore, if
an alarm activates during this time period, it will act as momentary or latching, depending upon the
specifications discussed in
Set Momentary Inputs
on page 38. A separate timed event must be scheduled to
enable these alarms using the Alarm Enable setting.
Settings:
Tour
Salvo
Preset
Alarm Enable
Alarm Type
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Pattern/Number
Events are identified using the event number setting discussed in
Event Number
. Events are further
differentiated using a pattern or number identifier. Alarms may be grouped in patterns A, B, or C, as discussed
in
Enable
Alarm Inputs
on page 37. Tours, salvos, and presets are identified using a number. For example,
preset 1 may be event 10.
Settings:
Presets:
001 to 080
Tours:
001 to 128
Salvos:
001 to 064
Alarms:
A, B, C
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Time of Day
Enter the time for the event (identified with the event number setting discussed in
Event Number
) to take
place. The Time of Day must be entered in 24-hour mode.
Settings:
Hours:Minutes
Keys:
Number keys across the top
Содержание NOVA V1400
Страница 2: ...This page intentionally left blank ...
Страница 3: ......
Страница 4: ...This page intentionally left blank ...
Страница 6: ...This page intentionally left blank ...
Страница 37: ...XX009 Rev 1099 NOVA V1400 Alarm Actions 25 Figure 2 Common Stack Mode Example ...
Страница 39: ...XX009 Rev 1099 NOVA V1400 Alarm Actions 27 Figure 3 Independent Stack Mode Example ...