XX009 Rev 1099 NOVA V1400
Alarm Actions
•
39
Menu Path: Main Menu
→
Alarm Actions
→
Set Input Controls
→
Set Momentary Inputs
Momentary Pattern
Select a momentary pattern and define which alarms will be momentary as discussed in the next section. Use
the Tab key to move the cursor from Momentary Pattern setting to the group of input numbers.
Settings:
A
B
C
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Default:
A
Momentary/Latching Alarms
Define the X-IA alarms that will be part of the pattern shown in Momentary Pattern at the top of the screen.
The Tab key is used to move back up to the Momentary Pattern setting so that the next pattern may be
defined. The X-IA alarms may be defined as momentary or latching.
Settings:
Momentary
Latching
Keys:
Numeric keypad’s + (plus) key or - (minus) key
Shift and numeric keypad’s + (plus) or - (minus) key to set all alarms past cursor
Default:
Latching
Set Closure Type
Alarms may be set to activate when the alarm contacts open or close. Closure type must be specified for each
X-IA alarm.
Menu Path: Main Menu
→
Alarm Actions
→
Set Input Controls
→
Set Closure Type