215
-
Fit the spring with the pin lock.
-
After ensuring that the spring is properly positioned into the housing, fit the vacuum
chamber cover.
-
Clean and blow the ambient pressure inlet filter sponge.
-
Check that the cut-off valve is in good condition
and that the membrane is not broken or
hardened.
-
Check the unloaded length of the spring.
Standard dimension:
Spring
0.945 in
(
24 mm
)
-
Fit the membrane with the metal pin positioned on the valve.
-
Fit the spring and the cover. The cover must have the vacuum inlet facing upwards.
10.11.12 Checking the Automatic Choke Device
10.11.12.1 Kehin CVK 30 Carburetor
-
Check that the piston (picture) exhibits no
scratches or oxidation and that it slides freely
into the seat.
-
Check the unloaded length of the spring.
-
Check that the piston sealing gasket exhibits
no deformations.