148
-
Tighten the two SAS piping screws at the
prescribed torque.
Tightening torques:
SAS piping screw
7.4±8.8 lbs·ft
(
10
±12
N·m
)
10.9
Checking the Secondary Air Box Valve
-
Remove the SAS valve.
-
Temporarily install the rubber sleeve at the
outlet of the SAS valve ensuring its seal.
-
Connect the mityvac vacuum pump to the rubber
sleeve as shown in the figure.
-
Set the pump onto vacuum mode.
-
Open the pump slowly.
-
Check that the one-way valve allows the
passage of air; this should generate a small
vibration.
Note:
The absence of vibration indicates a poor
sealing.
-
Switch the pump onto pressure mode.
-
Open the pump and check that there is an
increase in pressure. Small leaks are normal.
Note:
The incorrect operation of the one-way valve
can cause the overheating of the rubber sleeve and
filters.
-
Replace in case of faults.
Specific tools and equipment:
Mityvac pump
020329Y