![VESPA GT 200 Скачать руководство пользователя страница 153](http://html.mh-extra.com/html/vespa/gt-200/gt-200_workshop-manual_1008813153.webp)
153
10.10.2
Removing the Oil Sump and Pressure Adjusting By-Pass Valve
-
Remove the oil filler cap, the transmission cover,
the driving pulley assembly (with belt), and the
pinio n as described in chapter “Transmission”.
-
Drain the oil from the sump as previously
described.
-
Remove the seven screws shown in the figure
with the two rear brake fluid pipe clamps.
-
Remove the spring, the by-pass piston, the
gasket and the centering dowels shown in the
figure.
10.10.3
Checking the By-Pass Valve
-
Check the unloaded length of the spring.
Standard dimension:
By-pass valve spring length
2.11 in
(
54.2 mm
)
-
Check that the piston exhibits no signs of
superficial defects.
-
Ensure that it slides freely on the crankcase and
that it provides sufficient seal.
-
If not remove any dirt or replace any defective
parts.