Set Mode Item 70 [RX MD]*
Function: Selects the Receiving mode.
Available Values: AUTO/N-FM/AM/W-FM
Default: AUTO (Mode automatically changes according to operating frequency.)
Set Mode Item 71 [S SRCH]
Function: Selects the Smart Search Sweep mode.
Available Values: SINGLE/CONT
Default: SINGLE
SINGLE: The transceiver sweeps the current band once in each direction starting on the current
frequency. All channels where activity is present (up to 15 in each direction) are loaded into the
Smart Search memories. Whether or not all 31 memories are filled, the search stops after one
sweep in each direction.
CONT: The transceiver makes a sweep in each direction as with the “SINGLE” mode, but if all 31
channels are not filled after the first sweep, the radio continues sweeping until they are all filled.
Set Mode Item 72 [SAVERX]
Function: Selects the Receive-mode Battery Saver interval (“sleep” ratio)
Available Values: 0.2 - 0.9S (0.1S/step) or 1.0S - 10.0S (0.5S/step)
Default: 0.2 S (1:1)
Set Mode Item 73 [SAVETX]
Function: Enables/Disables the Transmitter Battery Saver.
Available Values: ON/OFF
Default: OFF
Set Mode Item 74 [SCN.LMP]
Function: Enables/Disables the Scan lamp while paused.
Available Values: ON/OFF
Default: ON
Set Mode Item 75 [SCN.RSM]
Function: Selects the Scan Resume mode.
Available Values: 2SEC - 10SEC/BUSY/HOLD
Default: 5 SEC
2 SEC - 10 SEC: The scanner will halt on a signal it encounters, and will hold there for the
selected resume time. If you do not take action to disable the scanner within that time period, the
scanner will resume even if the stations are still active.
BUSY: The scanner will halt on a signal it encounters. When the carrier has dropped because the
other station(s) ceased transmission, the scanner will resume. The Scan Re-start Delay time
(default interval: 2 seconds) is set by the Set Mode Item 67: RES.TIM.