FCC ID: K6620285X20
IC ID: 511B-20285X20
VX-3R Operating Manual
feature is activated when the radio was turned off, the radio also checks on the EAI frequency (Memory
Channel “EAI”) for activity.
EAI: Checks the EAI frequency (Memory Channel “EAI”) every 5 seconds. If a properly-coded signal is
received on the EAI frequency, the radio will turn itself on and then automatically transmit in
accordance with the setting of Set Mode Item 29: EAI.
OFF: Disables the Wakeup feature.
5. When you have made your selection, press the PTT switch to save the new setting and exit to normal
operation.
If you wish to disable the Wakeup feature, just repeat the above procedure, rotating the DIAL knob to select
“OFF” in step 4 above.
When the radio is turned off, the Wakeup feature will be engaged, and the “WAKEUP” notation will be seen
on the display.
You may cancel the Wakeup feature (complete power off) temporarily by pressing the [POWER] switch
while the Wakeup feature is engaged.
TX Battery Saver
The VX-3R also includes a useful Transmit Battery Saver, which will automatically lower the power output
level when the last signal received was very strong. For example, when you are in the immediate vicinity of
a repeater station, there generally is no reason to use the High Power output in order to achieve
full-quieting access to the repeater. With the Transmit Battery Saver, the automatic selection of Low Power
operation conserves battery drain significantly.
To activate the Transmit Battery Saver:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 73: SAVETX.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON” (thus activating the Transmit Battery Saver).
5. When you have made your selection, press the PTT switch to save the new setting and exit to normal
operation.
Disabling the BUSY Indicator
Further battery conservation may be accomplished by disabling the BUSY indicator while receiving a signal.
Use the following procedure:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 16: BSY.LED.
Vertex Standard Co., Ltd.