To set the receiving time interval:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 65: PRI.TMR.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.
4. Rotate the DIAL knob to select the desired time interval. Available selections are 0.1S - 0.5S
(0.5S/step) and 1.0S - 10S (0.5S/step).
5. When you have made your selection, press the PTT switch to save the new setting and exit to normal
operation.
R.F. Says: The default condition for this Set Mode Item is “5.0S.”
Priority Revert Mode
During Priority channel operation (Dual Watch), a special feature is available which will allow you to move
to the Priority Channel instantly, without waiting for activity to appear on the Priority Channel.
When this feature is enabled, and priority monitoring is engaged, just press the microphone’s PTT switch.
Operation will instantly revert to the Priority Channel.
To enable Priority Revert operation:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 65: PRI.RVT.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.
4. Rotate the DIAL knob so as to select “ON.”
5. When you have made your selection, press the PTT switch to save the settings and exit to normal
operation.
To disable Priority Revert operation, select “OFF” in step 4 above.
Automatic Lamp Illumination on Scan Stop
The VX-2R will automatically illuminate the LCD Lamp whenever the scanner stops on a signal; this allows
you to see the frequency of the incoming signal better at night. Note that this will, of course, increase the
battery consumption, so be sure to switch it off during the day (the default condition for this feature is “ON”).
The procedure for disabling the Scan Lamp is:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 74: SCN.LMP.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.