![Vertex Standard VX-3R Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/vertex-standard/vx-3r/vx-3r_operating-manual_1007578036.webp)
FCC ID: K6620285X20
IC ID: 511B-20285X20
VX-3R Operating Manual
selected resume time. If you do not take action to disable the scanner within that time period, the scanner
will resume even if the stations are still active.
BUSY: In this mode, the scanner will halt on a signal it encounters. When the carrier has dropped because
the other station(s) ceased transmission, the scanner will resume. In the case of constant-carrier signals
like Weather Station broadcasts, the scanner will likely remain on this frequency indefinitely. The Scan
Re-start Delay time (default interval: 2 seconds) is set by the Set Mode Item 76: SCN.STR.
HOLD: In this mode, the scanner will halt on a signal it encounters. It will not restart automatically; you must
manually re-initiate scanning if you wish to resume.
To set the Scan-Resume mode:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 75: SCN.RSM.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.
4. Rotate the DIAL knob to select the desired scan-resume mode described above.
5. When you have made your selection, press the PTT switch to save the new setting and exit to normal
operation.
R.F. Says: The default condition for this Set Mode Item is “5 SEC.”
To set the Scan-Restart Delay Time:
1. Press and hold in the [TXPO] key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 76: SCN.STR.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [TXPO] key momentarily to enable adjustment of this Set Mode Item.
4. Rotate the DIAL knob to select the desired Scan-Restart Delay Time. Available selections are 100 -
1000 MS (100 MS/step) and 1 - 10 SEC (0.5 SEC/step).
5. When you have made your selection, press the PTT switch to save the new setting and exit to normal
operation.
R.F. Says: The default condition for this Set Mode Item is “2 SEC.”
VFO Scannin
g
This mode allows you to scan on the VFO mode.
1. Select the VFO mode by pressing the [V/M] key, if necessary.
2. Press and hold in the [BAND] key for one second, and rotate the DIAL knob
while
holding in the
[BAND]
key
to select the bandwidth for the VFO scanner. Available selections are ±1 MHz, ±2 MHz, ±5
MHz, BAND, ALL, and PMS-X.
Vertex Standard Co., Ltd.
36