![Vertex Standard VX-3R Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/vertex-standard/vx-3r/vx-3r_operating-manual_1007578038.webp)
FCC ID: K6620285X20
IC ID: 511B-20285X20
VX-3R Operating Manual
- 999, and 000). The microprocessor will automatically select the next-available “free” Frequency Skip
Memory channel (a memory register on which no data has been stored). If you see that any blinking
channel number, it means that the channel currently has no data written on it (i.e. the channel is “free”).
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
2. Press the [F/W] key to store the frequency into the Frequency Skip Memory; it now is programmed to
be ignored during VFO scanning.
R.F. Says: The VX-3R has 100 VFO Frequency Skip Memory Channels.
To re-institute a frequency into the VFO scan loop:
1. Press the [V/M] key, if needed, to enter the MR mode.
2. Press and hold in the [F/W] key for 1/2 seconds, then rotate the DIAL knob to select the memory
channel to be re-instituted.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Press the [%] key to delete the channel from the Frequency Skip Memory; this will re-institute the
frequency into the VFO scan loop.
Memory Scanning
Memory scanning is similarly easy to initiate:
1. Set the radio to the Memory mode by pressing the [V/M] key, if necessary.
2. Press and hold in the [BAND] key for one second, and rotate the DIAL knob while
holding in the
[BAND]
key
to select the desired Memory Scan mode. Available selections are ALL CH, TAG1, TAG2,
BAND, and PMS-X.
ALL CH: The scanner sweeps all Memory channels.
TAG1:
The scanner sweeps only those Memory channels with the same first digit of the
alpha/numeric tag as the first channel on which scanning started.
TAG2:
The scanner sweeps only those Memory channels with the same first and second digits
of the alpha/numeric tag as the first channel on which scanning started.
BAND: The scanner sweeps only those Memory channels which are memorized on the same
operating band as the first channel on which scanning started.
PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See
page ?? for details.
Note: Do not forget to pull the DIAL knob to rotate the DIAL knob.
3. Release the [BAND] key to initiate scanning.
4. As with VFO scanning, the scanner will halt on any signal encountered that is strong enough to open
the squelch; it will then resume scanning according to the Scan-Resume mode set previously.
5. To cancel scanning, press the PTT switch or [V/M] key.
Vertex Standard Co., Ltd.
38