Attic Storage Lifting System
Applicable Product Models:
32, 32H, 32HX, 32W, 32WH, 32WHX
Roughing-In Notes:
58
RUFN-FRT .DWG
CAD:
32
-X
30
RUFN-SIDE .DWG
CAD:
32
-X
Tolerance for opening dimensions is +1/4” (6mm), -0” (-0mm).
The opening must be square and the side walls perpendicular.
Maximum joist height is 18” tall. See specification sheet for
maximum floor-to-floor height of specific models. For detailed
framing suggestions, see the
Versa Lift Installation Guide
.
TYPICAL FRAMING FOR
24” O.C. SOLID JOISTS
TYPICAL FRAMING FOR
16” O.C. SOLID JOISTS
Rough-In Guide for
Solid Lumber Joists
IMPORTANT NOTE:
The required finished opening is 30.5 x 58.5”
with smooth sidewalls. Whenever joist hanger
brackets are used to frame the opening, they
must be covered to prevent interference with
the lifting platform operation. 2 x 2” “L” shaped
flashing strips (4) are provided by BPG to cover
hanger brackets and nail head in the corners
of the lift opening.
IMPORTANT NOTE:
The required finished opening is 30.5 x 58.5”
with smooth sidewalls. Whenever joist hanger
brackets are used to frame the opening, they
must be covered to prevent interference with
the lifting platform operation. 2 x 2” “L” shaped
flashing strips (4) are provided by BPG to cover
hanger brackets and nail head in the corners
of the lift opening.
58
30
16”
CAD:
32RUFN-16-PLAN.DWG
24
58
30
RUFN-24-PLAN.DWG
CAD:
32