CFDV Series Gas Fireplace
20306739
9
72"
(1828 mm)
Minimum
6"
(152 mm)
Minimum
fP3012
wall clearances
Ceiling
Side Wall
CLEARANCES
CLEARANCES TO COMBUSTIBLES
Figure 8 –
Ceiling and Side Wall Clearances
FP3012
FIREPLACE LOCATION
Plan for the installation of your appliance. This includes
determining where the unit is to be installed, the vent con-
figuration to be used, framing and finishing details, and
whether any optional accessories (i.e. blower, wall switch,
or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, includ-
ing permits and inspections.
The following factors should be taken into consideration:
• Clearance to side-wall, ceiling, woodwork, and windows.
Minimum clearances to combustibles
must be main
-
tained.
• This fireplace may be installed along a wall, across a
corner, or use an exterior chase. Refer to
Figure 4
for
suggested locations.
• Location should be out of high traffic areas and away
from furniture and draperies due to heat from appliance.
• Never obstruct the front opening of the fireplace.
• Do
not
install in the vicinity where gasoline or other
flammable liquids may be stored.
• Vent pipe routing. See
Venting
section found in this
manual for allowable venting configurations.
• These units can be installed in a bedroom. See National
Fuel Gas Code ANSI Z233.1/NFPA 54 — (current
edition), the Uniform Mechanical Code — (current edi-
tion), and Local Building Codes for specific installation
requirements.
Figure 7 –
Locating Gas Fireplace
Y
E
A
B
C
D
F
B
LU584-1
Locating unit
2/4/99 djt
** Island (C) and room divider (D) installation is possible as long as the
horizontal portion of vent system (X) does not exceed 20' (6 m).
* When you install your fireplace in (D) room divider or (E) flat on wall
corner positions (Y), a minimum of 6" (102 mm) clearance must be
maintained from perpendicular wall and front of fireplace.
A
Flat on Wall
B
Cross Corner
C
Island**
D
Room Divider*
E
Flat on Wall Corner*
F
Chase Installation
Follow these instructions carefully to ensure safe
installation. Failure to follow instructions exactly
can create a fire hazard.
The appliance cannot be installed on a carpet, tile
or other combustible material other than wood
flooring. If installed on carpet or vinyl flooring, the
appliance shall be installed on a metal, wood or
noncombustible material panel extending full width
and depth of the appliance.
WARNING
Содержание 33CFDVNI