background image

100610-24 SPND.BODYB 

5055.101.B

MODEL:
SUPER  INSERT
DESIGN-D
SPND.BODYB

SAFETY NOTICE

If this stove is not properly installed, a house 

fi re may result. For your safety, follow the 

installation directions. Consult local building 

inspector or officials about restrictions and 

installation inspection requirements in your 

area.

Super Insert

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS

INSTALLATION 

AND OPERATING 

INSTRUCTIONS

TESTED and LISTED 
to ULC S628 / UL 1482

Meets the U.S. Environmental Protection 
Agency's July 1990 Particulate Emission
Standards 

Содержание SPND.BODYB

Страница 1: ...ections Consult local building inspector or officials about restrictions and installation inspection requirements in your area Super Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNE...

Страница 2: ...ustion Air 12 Operation 13 Wood Selection 13 How to Test Your Wood 13 Lighting the Fire 13 Normal Operation 13 Restarting After Extended or Overnight Burns 13 More Wood More Heat 14 Proper Draft 14 As...

Страница 3: ...equirements in your area Clearances Masonry or Factory Built Fireplace The minimum required clearances to surrounding combustible materials when installed into a masonry or factory built fireplace are...

Страница 4: ...ush to an adjacent combustible floor Ember protection Combustible floor in front of the fireplace insert must be protected from hot embers by non combustible material extending 16 to the firing side a...

Страница 5: ...5 SPND BODYB 100610 24 42 5 8 6 1 2 28 7 8 23 3 4 21 1 2 21 1 8 36 8 1 8 20 3 4 18 28 1 8 9 1 2 10 19 9 16 Dimensions...

Страница 6: ...t been in use for some time The existing fireplace damper is to be locked open or removed completely WARNING Donotremovebricksormortarfromyourexisting fireplace Exception Masonry or steel including th...

Страница 7: ...al around pipe Note A clean out door may be required under local codes when a direct flue connection is used Consult local codes 3 Push the Insert into position inside the fireplace and attach the con...

Страница 8: ...onnect the wires from the fans LHS RHS and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 4 Loosen the two bolts that secure...

Страница 9: ...ap switch Fig 17 refit ash lip sides and top Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side Wire placement is important to prevent damage...

Страница 10: ...f the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 19 4 Slide the assembled trim over the surround from the top Fig 18 5 Tighten the retaining screws at the bottom of e...

Страница 11: ...ure that the electric supply cord is located in the slots in the base of the surround 11 Oncethesurroundisfastenedtotheinsert inordertomaximize heated air discharge efficiency the surround can be pull...

Страница 12: ...urround to fireplace This will allow enough combustion air to enter the fireplace cavity and the Insert The knockouts in the casing sides and the O A cover can be removed to supplement air supply Fig...

Страница 13: ...has established itself open the door and add a few small logs Close door 5 Begin normal operation after a good coal base exists and wood has charred Normal Operation 1 Set air control to desired setti...

Страница 14: ...per hour 7500 BTU x 10 lbs 8 hrs 9375 BTU s per hr If you put 20 lbs of wood in your stove for an eight hour burn you will get 18 750 BTU s per hr 7500 BTU x 20 lbs 8 hrs 18 750 BTU s per hr This is o...

Страница 15: ...smoke densities occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed The heated wood generates smoke but without ample air the smokecannotburn Smoke free clean...

Страница 16: ...efore using the stove Replacement glass can be obtained from your Dealer The size required is 8 13 16 x 15 1 4 x 5 mm Ceramic glass must be used Do not substitute with any other type To remove broken...

Страница 17: ...le Assembly WODC 4147C 14 Flame Shield WINS 4513 15 Replacement Baffle Kit SSER DBAKIT 16 Brick Rail Set SSER RAILSET 17 Firebrick Set BRIC SSERA 18 Boost Manifold 4105 19 O A Cover 514 20 Air Shutter...

Страница 18: ...heat storage and the thermalinsulationkeepsthecombustionzonehot Active flamingtakesplaceduringthefirstpartoftheburn During this stage heat is stored in the mass of the unit and is later released slow...

Страница 19: ...2 Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won t Burn Overnig...

Страница 20: ...t Firebrick Installation This package contains 18 full size firebricks as well as 1 cut size brick With the heater in the upright position install firebricks as follows Place firebricks on the bottom...

Страница 21: ...21 SPND BODYB 100610 24 NOTES...

Страница 22: ...22 SPND BODYB 100610 24 NOTES...

Страница 23: ...CT FLUE CONNECTION ASSEMBLY OPTIONAL COMPONENTS MANTEL SHIELD SPND MSMBKA 3 VENT OFFSET SPND 3OFFSETA FAN KIT ELECTRICAL RATING 115V 60HZ 1 6 AMP ROUTE CORD AWAY FROM UNIT FOR USE WITH SOLID WOOD FUEL...

Страница 24: ...24 SPND BODYB 100610 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Technical Support 1 250 748 1184 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...

Отзывы: