VENTING INSTALLATION
Install Vertical Termination Cap
To attach the vertical termination cap, slide the inner col-
lar of the cap into the inner flue of the vent section and
place the outer collar of the cap over the outer flue of the
vent section.
Secure the cap by driving the three self-tapping screws
(supplied) through the pilot holes or dimples in the outer
collar of the cap into the outer flue of the vent.
Figure 63
Termination Cap
(1 of 3)
Storm
Collar
Screws
Caulk
Attaching Flexible Venting to Vertical
Termination Kit
1. Attach the inner flex adapter to the inner pipe of the rig
-
id pipe length using three (3) self tapping #10 screws.
2. Attach the outer flex adapter to the outer pipe of the
rigid pipe lenth using three (3) self tapping #10 screws.
3. Attach the 4" and 6-5/8" flex pipe to the flex pipe
adapter in the same manner as the starting adapter.
Figure 65
Figure 63 –
Secure with Screws
Figure 64 –
Typical Vertical Flex Vent Installation
Figure 65 –
Typical Vertical Termination Connection
Termination
Cap
Storm Collar
Flashing
Rigid Pipe
Length
Flex to Pipe
Adapter
UL1777 Flex Pipe
Flex Adapter Starter
Roof Support
Refer to Figures
5 & 6
Firestop
Secure Screws
(3 Places Equidistant
Just Above Gear
Clamp)
Gear
Clamp
2" Flexible Pipe
and Adapter Outer
Collar Overlap
Rigid Pipe
Length
Flex Adapter
Outer
UL1777
Flex Vent
Flex Adapter
Inner
Flex Adapter
Outer
Flex Adapter
Inner