OPERATING INSTRUCTIONS – MILLIVOLT
PILOT
OF
F
P
IL
O
T
ON
FP1935
control knob pilot
Continued on next page
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
•
Soap and water solution
•
An approved leak testing spray
•
Electronic sniffer
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound
can set off electronic sniffers.
Check for gas leaks in each of the following locations:
•
Pipe from the gas supply line connection to the gas valve
•
Burner connections
•
Field made joints / gas shutoff valve
•
Pilot
•
Factory made joints
•
Each joint or connection
•
All joints on valve and control body
1. Depress and turn knob counterclockwise
to
pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for 30 - 60 seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
LIGHTING PILOT
Pilot Position
LIGHTING PILOT FOR THE FIRST TIME
Do NOT
use open flame to check for gas leaks.
WARNING
If using a soap and water solution to test for leaks,
DO NOT spray solution onto control body.
WARNING
The control is fitted with a safety interlock device which prevents unsafe ignition of the pilot
burner after the control knob has been turned to the OFF position. The knob may only be
rotated back to the PILOT position after the safety magnet has been released (approximately
60 seconds). You will hear a “click” when the safety magnet releases.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation.
Damaged knobs may result in serious injury.
WARNING