Initial Setup Of The Console Using Workflow Wizard
Setup>Pumps and Lines>Pumps
40
Setup>Pumps and Lines>Pumps
This screen lets you configure the site's pu
m
ps that will be
m
onitored by the console.
Select a pu
m
p fro
m
the icon list on the botto
m
of the screen to configure.
Configured
Touch the radio button to enable or disable the selected pu
m
p.
NOTE: Set to Enabled only after completing all of the settings for this pump.
Pump Label
Touch to enter a description for this pu
m
p.
Mode
Touch to deter
m
ine how the pu
m
p is controlled:
•
TLS Pump Control
- Pu
m
p is controlled or actuated locally by the console.
•
Pump Sense
- A pu
m
p request signal is sent to the console to turn on/off the pu
m
p (this
signal also acts as a tank "active" signal to the console).
•
External Pump Control
- Pu
m
p is controlled externally to the console and identifies
tanks that are line
m
anifolded together.
Tank
Touch to assigned the tank assigned to the selected pu
m
p. NOTE: There
m
ay be both config-
ured and non-configured ite
m
s on this field's drop-down list (non-configured ite
m
s will be
prefixed by a
"!
).
Pump Control
[Field only enabled when the
Mode
field is set to "
TLS Pump Control
"].
A device that responds to dispense requests and actuates the selected pu
m
p. These devices
are nor
m
ally relays that have been configured and assigned as pu
m
p controlling devices in
Setup>Devices (“RELAY SETUP”).
Pu
m
p control relay assign
m
ents are usually unique for each pu
m
p. A warning dialog will dis-
play if the pu
m
p control selected is already assigned to another pu
m
p (this alert is not an
alar
m
or error since so
m
e sites use a single pu
m
p control output for
m
ore than one pu
m
p).
NOTE: There
m
ay be both configured and non-configured ite
m
s on this field's drop-down list
(non-configured ite
m
s will be prefixed by a
"!
).
Pump Sense
[Field only enabled when the
Mode
field is set to "
TLS
Pump Control
" or "
Pump Sense
"].
The external input that tells the console when the pu
m
p is on
or off. Pu
m
p sense inputs are configured and assigned in
Setup > Devices (“EXTERNAL INPUT SETUP”). More than
one pu
m
p
m
ay use the sa
m
e pu
m
p sense input.
NOTE: There
m
ay be both configured and non-configured
ite
m
s on this field's drop-down list (non-configured ite
m
s will
be prefixed by a ‘!’).
Line
[Read-only field]. The line identifier of the selected pu
m
p
(shows "
Not Assigned
" if that is the case).
Pump Relay Monitor Device
[Available with PLLD]. The external input that generates a
pu
m
p relay alar
m
when the console suspects a relay is stuck
or when the pu
m
p has been running continuously for a
period exceeding the Max Run. The device is configured and
assigned in Setup>Devices (“EXTERNAL INPUT SETUP”).
Stuck Relay
[Available with PLLD]. The console suspects a pu
m
p relay is
"stuck" when the pu
m
p relay signal is inactive but the pu
m
p
m
onitor indicates the pu
m
p is powered. When a pu
m
p relay
fault detected by the console has persisted beyond this
delay, a Pu
m
p Relay Alar
m
is generated. Touch to enter a
Stuck Relay delay ti
m
e fro
m
5 to 600 seconds. The default is
60 seconds.
Max Run Time
[Available with PLLD]. When the console detects that a
pu
m
p has running continuously for longer than the ti
m
e
entered in this field. Touch to enter ti
m
e fro
m
1 to 24 hours.