46 Rainger Linear
OPERATION
Closed Delivery
Start Up
12. Slowly fill the system with water.
13. If equipped with an Engine/Pump to boost pres-
sure after the hose, follow steps 4 through 8 to
start the engine/pump.
14. Refer to the appropriate Control Panel Owner’s
Manual for control panel operating procedures.
15. If equipped with an Engine/Generator and or
Pump, hold the safety button in and move the
remote shutdown toggle switch to the enabled
position when the system is running.
With the remote shutdown toggle switch in the
engaged position the engine will stop running if
the system shuts down. See Figure 46-1.
16. If equipped with an Engine/Generator, check the
voltmeter reading again while the generator is un-
der load to verify that the generator is producing the
correct Nominal Supply Voltage for this machine. See
Figure 46-2.
!
CAUTION
• DO NOT OPERATE THE MACHINE IF THE
VOLT METER READS BELOW THE MINIMUM
ALLOWED VOLTAGE OR ABOVE THE MAXI-
MUM ALLOWED VOLTAGE. SEE FIGURE 46-2.
• OPERATING THE MACHINE OUTSIDE THESE
LIMITS COULD CAUSE DAMAGE TO THE
DRIVE MOTORS AND OTHER ELECTRICAL
COMPONENTS.
• CORRECT THE LOW VOLTAGE PROBLEM
BEFORE RESUMING OPERATION.
3
1
2
4
Figure 46-1 1. Safety Button
2. Toggle Switch
3. Engine Start Switch
4. Water Pressure Gauge Reset
Nominal
Supply Voltage
Maximum
Allowed Voltage
Minimum
Allowed Voltage
480 VAC @ 60Hz
505 VAC
440 VAC
415 VAC @ 50Hz
420 VAC
375 VAC
400 VAC @ 50Hz
420 VAC
365 VAC
380 VAC @ 50Hz
420 VAC
355 VAC
230 VAC @ 60Hz
253 VAC
220 VAC
120 VAC @ 60Hz
132 VAC
105 VAC
110 VAC @ 50Hz
121 VAC
95 VAC
Figure 46-2
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...