![Valley Rainger Linear Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/valley/rainger-linear/rainger-linear_owners-manual_3240098033.webp)
Rainger Linear 33
OPERATION
Machine Operation
The Rainger Linear was designed to be used on relatively level fields should not be used on any severe rolling or
sloping terrain. The cart path must be maintained flat and free of any ruts or tracks which would force side loads
into the cart frame. Should ruts develop in the cart path, the owner/operator should grade the surface smooth
and maintain cart path flat and free of ruts or tracks during irrigation season.
For proper operation of the Rainger Linear machine, the Control Panel Owner’s Manual and Rainger Linear
Owner’s Manual must be used together.
The Control Panel Owner’s Manual includes safety guidelines and explains the basic operation of the control
panel itself, including how to start/stop the machine, change running direction and change water application
amounts.
The Rainger Linear Owner’s Manual includes safety guidelines and explains the operation of the Rainger Linear
machine including how to establish wheel tracks, methods of operation, closed delivery operation, open delivery
operation, swing around operation, electric cord drag operation with hose and cord positioning.
All owner’s, operators and maintenance personnel MUST read and understand the Control Panel Owner’s
Manual and the Rainger Linear Owner’s Manual.
Overwatering Timer
The overwatering timer located in the central pulse
tower box is a safety device used to shut the machine
off should one or both of the end towers fail to move.
The overwatering timer is set by the operator. See
Figure 33-1.
!
DANGER
• THE TOWER BOXES CONTAIN HIGH VOLT-
AGE! 480 VOLTS CAN KILL.
• ALWAYS DISCONNECT ELECTRICAL POW-
ER BEFORE SETTING THE OVERWATERING
TIMER.
• ALWAYS REPLACE ANY COVER THAT WAS
REMOVED TO MAKE OVERWATERING TIMER
ADJUSTMENT.
Refer to the chart for suggested overwatering timer
settings based on the control panel percent timer
setting. The times shown in the chart are actual min-
utes that the overwatering timer will allow the central
pulse tower box drive unit to stand still before it shuts
the machine off. See Figure 33-2.
NOTE
• An overwatering timer setting of less than
the Suggested Overwatering Timer Setting
may be used when chemigating.
Each time the central pulse tower box drive unit
moves the overwatering timer is reset and another
time out cycle begins.
1
Figure 33-1 1. Overwatering timer
OVERWATERING TIMER SETTINGS
The overwatering timer should be set in relation-
ship to the percent timer setting.
Percent
Timer Setting
Suggested
Overwatering
Timer Setting
90%
20 Minutes
80%
20 Minutes
60%
20 Minutes
40%
20 Minutes
30%
28 Minutes
10%
36 Minutes
Figure 33-2
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...