102 Rainger Linear
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Pump fails to prime
Leak on the inlet side of pump, inlet
sucking air.
Check inlet tube seals.
Check optional flow meter fittings
and seals.
Make sure water level in ditch is
correct.
Make sure inlet is submerged to
the correct depth.
Optional water shut off valve fails
to operate.
External water filter plugged.
Clean or replace external water
filter.
Tube line plugged.
Check tube lines for blockage.
Solenoid valve plugged.
Clean solenoid valve passages.
Solenoid valve failure.
Contact your local Valley dealer.
Electrical problem.
Contact your local Valley dealer.
Side inlet elbow does not rotate
properly during auto reverse.
Side inlet elbow stop(s) are out of
adjustment.
Adjust side inlet elbow stops.
Longitudinal scratches or cuts on
the hose.
Sharp project in runway.
Keep the lanes clean.
Check the equipment for sharp
edges or protrusions.
Vertical breaks in the hose.
Improper bend at loop, causing the
hose to kink.
Maintain recommended bend
diameter.
Insufficient water pressure.
Increase the pressure at the pump
to a minimum of 70 psi (483 kPa).
Water blisters forming behind the
coupling.
Improperly applied coupling.
Take care to apply correctly
according to the manufacturer's
instructions.
Tube cut while coupling is being
installed.
Take care to apply correctly
according to the manufacturer's
instructions.
Hose cover checking cracking at
the edges.
Stored incorrectly near electrical
equipment.
Store 150 ft (46 m) from electrical
motors.
Stored for extended period of time
in direct sunlight.
Store hose in cool, dry protected
areas.
Operation
Содержание Rainger Linear
Страница 2: ...2 Rainger Linear This page was left blank intentionally...
Страница 6: ...6 Rainger Linear TABLE OF CONTENTS This page was left blank intentionally...
Страница 36: ...36 Rainger Linear OPERATION This page was left blank intentionally...
Страница 58: ...58 Rainger Linear OPERATION This page was left blank intentionally...